Experimental Study on Performance of Two-phase Ejector Refrigeration Cycle System with Two-throat Nozzle
نویسندگان
چکیده
The two-phase ejector refrigeration cycle (TPERC) system with a two-throat nozzle ejector was investigated experimentally, and the entrainment ratio of the ejector and the COP of the system were compared with those of the ejector with Laval nozzle and its TPERC system respectively. The experimental results indicate that under the working condition of the evaporating/condensing temperatures 1°C/45 , °C the entrainment ratio of the two-throat nozzle ejector with different geometric size is greater than that of the Laval nozzle ejector, the maximum increment of the entrainment ratio is about 18%, and the COP of the TPERC system with two-throat nozzle ejector is greater than that of the TPERC system with Laval nozzle ejector, the maximum increment of the COP is about 12%. Under the fixed evaporating temperature 1 , the entrainment ratio of the two °C -throat nozzle ejector and the Laval nozzle ejector achieve the maximum as the condensing temperature is 45 . Under the fixed condensing temperature 50 °C °C, the entrainment ratio of the two types of ejectors achieves the maximum as the evaporating temperature is 3 . °C
منابع مشابه
Parametric Study of a Vapor Compression Refrigeration Cycle Using a Two-Phase Constant Area Ejector
There are several ways of improving the performance of a vapor compression refrigeration cycle. Use of an ejector as expansion device is one of the alternative ways. The present paper aims at evaluate the performance improvement of a vapor compression refrigeration cycle under a wide range of operating conditions. A numerical model is developed and a parametric study of important parameters suc...
متن کاملAnalysis of a Two Phase Flow Ejector For Transcritical CO2 Cycle
This paper presents the analysis of a two phase flow ejector for the transcritical CO2 cycle. A detailed simulation model of a two phase flow ejector was developed. A controllable ejector expansion device was designed, constructed, and installed in a transcritical CO2 experimental air conditioning system. System-level experimental results were obtained at different operation conditions and vari...
متن کاملA New Control Mechanism for Two-Phase Ejector in Vapor Compression Cycles Using Adjustable Motive Nozzle Inlet Vortex
Expansion work recovery by two-phase ejector is known to be beneficial to vapor compression cycle performance. However, one of the biggest challenges with ejector vapor compression cycle is that the ejector cycle performance is sensitive to working condition changes which are common in real world applications. Different working conditions require different ejector geometries to achieve maximum ...
متن کاملExergy, exergoeconomic and exergoenvironmental studies and optimization of a novel triple-evaporator refrigeration cycle with dual-nozzle ejector using low GWP refrigerants
In this work, a novel dual-nozzle ejector enhanced triple-evaporator refrigeration cycle (DETRC) without separator is proposed to improve the performance of the conventional ejector one (CETRC). The performance of DETRC is analyzed and compared with CETRC in term of energy coefficient of performance (COPen). Under given operating conditions, the COPen improvement of the no...
متن کاملPerformance Investigation of Two Two-Stage Trans-Critical Carbon Dioxide Refrigeration Cycles Ejector and Internal Heat Exchanger
In the present work, the performances of improved two-stage multi inter-cooler trans- critical carbon dioxide (CO2) refrigeration cycles with ejector and internal heat exchanger have been examined. In the new improved cycles, an internal heat exchanger is append to the cycles. Also, second inter-cooler in improved cycles, cooled with the refrigeration of the cycle, so that in first c...
متن کامل