Haemodynamic changes in ipsilateral and contralateral fingers caused by acute exposures to hand transmitted vibration.

نویسندگان

  • M Bovenzi
  • M J Griffin
چکیده

OBJECTIVES To investigate changes in digital circulation during and after exposure to hand transmitted vibration. By studying two frequencies and two magnitudes of vibration, to investigate the extent to which haemodynamic changes depend on the vibration frequency, the vibration acceleration, and the vibration velocity. METHODS Finger skin temperature (FST), finger blood flow (FBF), and finger systolic pressure were measured in the fingers of both hands in eight healthy men. Indices of digital vasomotor tone-such as critical closing pressure and vascular resistance-were estimated by pressure-flow curves obtained with different hand heights. With a static load of 10 N, the right hand was exposed for 30 minutes to each of the following root mean squared (rms) acceleration magnitudes and frequencies of vertical vibration: 22 m.s-2 at 31.5 Hz, 22 m.s-2 at 125 Hz, and 87 m.s-2 at 125 Hz. A control condition consisted of exposure to the static load only. The measures of digital circulation and vasomotor tone were taken before exposure to the vibration and the static load, and at 0, 20, 40, and 60 minutes after the end of each exposure. RESULTS Exposure to static load caused no significant changes in FST, FBF, or indices of vasomotor tone in either the vibrated right middle finger or the non-vibrated left middle finger. In both fingers, exposure to vibration of 125 Hz and 22 m.s-2 produced a greater reduction in FBF and a greater increase in vasomotor tone than did vibration of 31.5 Hz and 22 m.s-2. In the vibrated right finger, exposure to vibration of 125 Hz and 87 m.s-2 provoked an immediate vasodilation which was followed by vasoconstriction during recovery. The non-vibrated left finger showed a significant increase in vasomotor tone throughout the 60 minute period after the end of vibration exposure. CONCLUSIONS The digital circulatory response to acute vibration depends upon the magnitude and frequency of the vibration stimulus. Vasomotor mechanisms, mediated both centrally and locally, are involved in the reaction of digital vessels to acute vibration. The pattern of the haemodynamic changes in the fingers exposed to the vibration frequencies used in this study do not seem to support the frequency weighting assumed in the current international standard ISO 5349.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Response of finger circulation to energy equivalent combinations of magnitude and duration of vibration.

OBJECTIVES To investigate the acute response of finger circulation to vibration with different combinations of magnitude and duration but with the same "energy equivalent" acceleration magnitude according to current standards for hand transmitted vibration. METHODS Finger skin temperature (FST) and finger blood flow (FBF) were measured in the middle fingers of both hands of 10 healthy men who...

متن کامل

Vibrotactile perception and effects of short-term exposure to hand-arm vibration.

This study clarifies whether the established frequency weighting procedure for evaluating exposure to hand-transmitted vibration can effectively evaluate the temporary changes in vibrotactile perception thresholds due to pre-exposure to vibration. In addition, this study investigates the relationship between changes of the vibrotactile perception thresholds and the normalized energy-equivalent ...

متن کامل

Changes over a workshift in aesthesiometric and vibrotactile perception thresholds of workers exposed to intermittent hand transmitted vibration from impact wrenches.

OBJECTIVES To investigate the changes over a workshift in fingertip tactile perception thresholds in users of impact wrenches exposed to intermittent hand transmitted vibration. A further aim was to assess the relation between acute changes in tactile sensation, sensorineural disorders, and vibration dose. METHODS The study populations consisted of 30 workers exposed to vibration (16 men and ...

متن کامل

A new method for the experimental assessment of finger haemodynamic effects induced by a hydraulic breaker in operative conditions.

The haemodynamic effects, in terms of grip force and hand-transmitted accelerations, produced on the fingers of 10 healthy subjects by operation of a hydraulic breaker held with a low or a high grip were investigated with a new experimental set-up. A novel apparatus consisting of a capacitive sensor matrix and a laser Doppler vibrometer was used to measure the two parameters during breaker oper...

متن کامل

The functional anatomy of motor recovery after stroke in humans: a study with positron emission tomography.

We have studied regional cerebral blood flow changes in 6 patients after their recovery from a first hemiplegic stroke. All had a single well-defined hemispheric lesion and at least a brachial monoparesis that subsequently recovered. Each patient had 6 measurements of cerebral blood flow by positron tomography with 2 scans at rest, 2 during movement of fingers of the recovered hand, and 2 durin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Occupational and environmental medicine

دوره 54 8  شماره 

صفحات  -

تاریخ انتشار 1997