The reproducibility of cephalometric measurements: a comparison of analogue and digital methods.
نویسندگان
چکیده
The aim of this study was to compare the reproducibility of longitudinal cephalometric measurements between analogue and digital methods using two different resolutions. Cephalometric radiographs of 20 patients were selected at the start (T1) and end (T2) of treatment: 24 cephalometric variables were calculated at T1 and T2, and their increments (T2 - T1) were also evaluated. All measurements were performed twice by two observers. Quality of methods [analogue, digital: 300 and 600 dots per inch (DPI) resolution] was evaluated by comparing the reliability coefficients and the total error between the digital and analogue methods. The inter-observer agreement was good. The 300 DPI was comparable to the analogue method. The reproducibility for the variables was comparable, but mandibular incisor increments tended to show better results with the 300 DPI method, whereas skeletal jaw relationship increments were not reliable with either method. Maxillary incisor increments, however, were reliable with both methods. The 300 and 600 DPI resolutions were found to be comparable. Scanning of cephalometric radiographs at a resolution of 300 DPI is sufficient for clinical purposes and comparable to analogue cephalometrics. However, all methods were found to be poor in assessing skeletal jaw relationships longitudinally.
منابع مشابه
Validity and reproducibility of cephalometric measurements obtained from digital photographs of analogue headfilms.
UNLABELLED The emerging market of digital cephalographs and computerized cephalometry is overwhelming the need to examine the advantages and drawbacks of manual cephalometry, meanwhile, small offices continue to benefit from the economic efficacy and ease of use of analogue cephalograms. The use of modern cephalometric software requires import of digital cephalograms or digital capture of analo...
متن کاملA comparison on dentofacial cephalometric measurements between two mouth breathing groups with anterior and posterior obstructions of nasal airway
A comparison on dentofacial cephalometric measurements between two mouth breathing groups with anterior and posterior obstructions of nasal airway zaeim* - Dr. M.R. Baghersad** Dr. M.H. Toodeh * - Assistant Professor of Oral Orthodontics Dept. - Faculty of Dentistry - Yazd University of Medical Sciences. ** - Dentist. Background and aim: The goal of this study was to compare dentofacial cep...
متن کاملComparison of cephalometric measurements with digital versus conventional cephalometric analysis.
The aim of this study was to evaluate the accuracy and reliability of angular and linear cephalometric measurements using a computerized method of direct digital radiographs. This was then compared with the measurements obtained with a computerized method that uses a digitizing pad and hand tracing of printout radiographs. Pre-treatment digital cephalometric radiographs of 125 patients were tra...
متن کاملThe assessment of accuracy and reproducibility of cephalometric analyses using Computer- Assisted Simulation System for Orthognathic Surgery (CASSOS) software
Cephalometric analyses using computer software have more advantages than manual analyses. However, the software should be evaluated for the accuracy and reproducibility before it can be used. The aims of the present study were: 1) to compare the differences in accuracy and precision between utilizing scanned images and soft copy images with the software 2) to assess the reproducibility of softw...
متن کاملAccuracy and precision of measurements obtained from conventional cephalograms and CBCT scan in orthodontics linear diagnostic measurements
Background and Purpose: Due to the important role of imaging in the diagnosis and treatment plan in orthodontics, CBCT (Cone Beam Computed Tomography) images because of their three-dimensional nature, can minimize the disadvantages of two-dimensional images such as magnification, distortion, or superimposition. The purpose of this study was to evaluate the accuracy of conventional cephalograms...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of orthodontics
دوره 24 6 شماره
صفحات -
تاریخ انتشار 2002