Free-breathing late gadolinium enhancement CMR with a fixed short scan time using CosMo

نویسندگان

  • Mehdi H Moghari
  • Hussein Rayatzadeh
  • Susie Hong
  • Raymond H Chan
  • Mehmet Akcakaya
  • Beth Goddu
  • Lois A Goepfert
  • Kraig V Kissinger
  • Warren J Manning
  • Reza Nezafat
چکیده

Methods CosMo was implemented on a Philips 1.5T CMR system to prospectively acquire high resolution undersampled k-space LGE. The inner 10% of k-space is acquired within a 7 mm gating window. The rest of k-space is acquired without gating to finish the scan in a fixed time. Retrospectively, the k-space data acquired outside the gating window is discarded to generate the undersampled k-space. The discarded k-space is estimated using compressed sensing [4,5] to generate the images. In vivo studies were conducted on 10 healthy subjects (6 female, 30.1 ± 16.8 yr) and 9 patients (6 male, 56.8 ± 11.7 yr). The 3D LGE were acquired using the CosMo and following imaging parameters: TE/TR/a = 2.4 ms/ 5.2 ms/25°, spatial resolution of 1.7×1.7×1.7 mm. The images were graded by consensus of two expert readers in terms of diagnostic value, based on a 2-point scale (1-yes; 2-no), and respiratory motion artifacts, based on a 4-point scale (1-severe; 4-none). Results Figure 1 demonstrates reformatted LGE images acquired from a suspected pericarditis patient using the conventional LGE and CosMo. Figure 2 displays reformatted LGE images acquired from a patient using the conventional LGE and CosMo. Although the scan time of both acquisitions was identical (≈8min.), the through-plane resolution of CosMo LGE was higher than the conventional (4.0 mm vs. 1.7 mm). The size and morphology of enhancements in the high resolution CosMo LGE is more localized compared with the conventional acquisition due to less partial volume averaging. All images acquired from 19 volunteers using the CosMo LGE were identified as diagnostic with a respiratory motion artifact score of 3.1 ± 0.7, and gating efficiency of 94 ± 4%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3D free-breathing late gadolinium enhancement 3T MRI: comparison with standard 2D Imaging

Background Clinical cardiovascular magnetic resonance imaging (CMR) is routinely performed during multiple breathholds in predefined 2D image orientations. 3D CMR is desirable, since it allows post-acquisition reformatting in any desired imaging plane. However, 3D CMR is hampered by long breath-hold duration, introducing patient discomfort and technical limitations. These limitations can be ove...

متن کامل

Myocardial fibrosis delineation in late gadolinium enhancement images of Hypertrophic Cardiomyopathy patients using deep learning methods

Introduction: Accurate delineation of myocardial fibrosis in Late Gadolinium Enhancement on Cardiac Magnetic Resonance (LGE-CMR) has a crucial role in the assessment and risk stratification of HCM patients. As this is time-consuming and requires expertise, automation can be essential in accelerating this process. This study aims to use Unet-based deep learning methods to automate the mentioned ...

متن کامل

The utility of free-breathing, motion-corrected late gadolinium enhancement for right ventricular fibrosis imaging in congenital heart disease

Background Ventricular fibrosis in adult congenital heart disease (ACHD) has been shown to relate to adverse clinical markers.[1,2] Novel free-breathing, motion-corrected late gadolinium enhancement cardiovascular magnetic resonance (LGE CMR) has been shown to be advantageous in quantifying LV LGE, but has not been evaluated for RV LGE. [3] It may therefore also be beneficial in ACHD patients, ...

متن کامل

Left ventricular function, aortic velocity, and late gadolinium enhancement assessed by real-time and single shot CMR is comparable to breath-held segmented imaging: a prospective study

Methods Thirteen patients referred to the CMR lab for evaluation of undiagnosed cardiomyopathy were prospectively enrolled. All patients were in regular cardiac rhythm and able to breath-hold. Standard segmented k-space images (including cine, velocity mapping (VM), and late-gadolinium enhancement (LGE)) were acquired during breathhold; real-time images (including cine, VM, and LGE) were acquir...

متن کامل

Diagnostic performance of treadmill exercise cardiac magnetic resonance: the prospective, multicenter EXACT trial

Methods Patients clinically referred for treadmill stress SPECT for the evaluation of known or suspected CAD were prospectively enrolled across 4 centers. After rest Tc99m SPECT imaging, patients underwent resting cine CMR. In-room stress was then performed using an MR-compatible treadmill with continuous 12-lead ECG monitoring and the Bruce exercise protocol. At peak stress, Tc99m was injected...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2012