Optical thickness monitoring sensitivity improvement using graphical methods.

نویسنده

  • R R Willey
چکیده

Semidirect level monitoring has error compensation capabilities of potential benefit to optical coatings of certain types. A review of the principles of level monitoring using circle diagrams shows how to design a level monitoring scheme for various cases, including the use of precoated monitoring chips. The film thickness sensitivities for various optical monitoring strategies differ considerably. Optimum level trigger point monitoring offers improved sensitivity of change in reflectance vs change in optical thickness. This procedure is also expected to give small thickness errors when optically monitored. Optimum level trigger point monitoring, and its application, is fully described.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation between Spectral Domain Optical Coherence Tomography and Microperimetric Findings before and after Intravitreal Bevacizumab Injection in Wet Age Related Macular Degeneration

Results: There was statistically significant improvement in macular thickness and best corrected visual acuity (BCVA) but improvement in macular sensitivity was not significant. There was significant positive correlation between baseline visual acuity (VA) ≤ 3/60 and change in VA. No significant correlation between improvement in macular thickness and change in macular sensitivity. No significa...

متن کامل

Reversible NO2 Optical Fiber Chemical Sensor Based on LuPc2 Using Simultaneous Transmission of UV and Visible Light

In this paper, an NO2 optical fiber sensor is presented for pollution monitoring in road traffic applications. This sensor exploits the simultaneous transmission of visible light, as a measurement signal, and UV light, for the recovery of the NO2 sensitive materials. The sensor is based on a multimode fiber tip coated with a thin film of lutetium bisphthalocyanine (LuPc2). The simultaneous inje...

متن کامل

Simulation of errors in the monitoring of narrow bandpass filters.

Narrow bandpass filters are extremely sensitive to errors in the optical thickness of the layers, but they have an extraordinary inherent capability to compensate for these errors. Graphical examples of errors of differing magnitudes and types with and without compensation are shown with computer simulation of the optical monitoring techniques. This allows the estimation of what magnitude of er...

متن کامل

Single intravitreal bevacizumab injection effects on contrast sensitivity in macular edema from branch retinal vein occlusion.

PURPOSE To evaluate the effect of a single intravitreal bevacizumab injection on visual acuity, contrast sensitivity and optical coherence tomography-measured central macular thickness in eyes with macular edema from branch retinal vein occlusion. METHODS Seventeen eyes of 17 patients with macular edema from unilateral branch retinal vein occlusion were treated with a single bevacizumab injec...

متن کامل

Adjusting Circumpapillary Retinal Nerve Fiber Layer Profile Using Retinal Artery Position Improves the Structure-Function Relationship in Glaucoma.

PURPOSE To investigate whether correcting the circumpapillary retinal nerve fiber layer (cpRNFL) thickness profile, using retinal artery position and papillomacular bundle tilt, can improve the structure-function relationship in glaucoma patients. METHODS Spectral-domain optical coherence tomography (SD-OCT) and visual field measurements were conducted in 142 eyes of 90 subjects with open ang...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 26 4  شماره 

صفحات  -

تاریخ انتشار 1987