Time-integrated monitoring of dioxin-like polychlorinated biphenyls (dl-PCBs) in aquatic environments using the ceramic toximeter and the CALUX bioassay.

نویسندگان

  • Amr Addeck
  • Kim Croes
  • Kersten Van Langenhove
  • Michael S Denison
  • Ahmed S Afify
  • Yue Gao
  • Marc Elskens
  • Willy Baeyens
چکیده

Ceramic passive samplers or toximeters (packed with active carbon 1%, w/w, on celite), in combination with the CALUX bioassay have been used as a time-integrated monitoring technique for dissolved dioxin-like PCBs in urban and industrial wastewaters. The technique showed to be reliable during laboratory experiments: (1) PCB-126 amounts extracted from the passive samplers increased linearly with the time of exposure and (2) PCB-126 concentrations calculated from the amounts accumulated by the passive samplers were in agreement with their concentrations in the testing solution. Afterwards the toximeters were applied in the field. Two sampling sites located in Egypt were chosen: the Belbeis drainage canal, and the EMAK paper mill. A total of 18 ceramic toximeters were exposed to the wastewater in both sampling sites for a maximum period of 4 weeks. Two samplers were collected weekly from each site to monitor the increase in target analytes over time. Extracts were analyzed using the CALUX bioassay and the total dioxin-like PCB toxicity was reported for the aqueous phase (water column), as well as the solid phase (sediment and sludge) in both sampling sites. The time-weighted average concentration (TWA) of dl-PCBs in wastewater of the paper mill during the sampling period ranged between 7.1 and 9.1 pg-BEQL(-1), while that of the drainage canal ranged between 9.5 and 12.2 pg-BEQL(-1). The dl-PCBs in the fibrous sludge (paper mill) and bottom sediment (drainage canal) were 0.5 and 0.4 pg-BEQg(-1) dry-weight, respectively. The organic-carbon normalized partition coefficients between sediment and water (logKoc) for the paper mill and the canal were 2.4 and 4.3, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of PCDD/Fs and dioxin-like PCBs in atmospheric deposition samples from the Flemish measurement network: correlation between the CALUX bioassay and GC-HRMS.

Since the CALUX (Chemically Activated LUciferase gene eXpression) bioassay is a fast, sensitive and inexpensive tool for the analysis of a high number of samples, the use of this technique in routine analysis of atmospheric deposition samples may be a valuable alternative for GC-HRMS. In this study, a validated CALUX method was used for the analysis of PCDD/Fs and dioxin-like PCBs in more than ...

متن کامل

Dioxin analysis in water by using a passive sampler and CALUX bioassay.

Passive sampling of organic pollutants is a new trend in environmental monitoring and analysis. Passive samplers are being developed to overcome the drawbacks of the conventional snapshot sampling approach. The ceramic toximeter is a promising passive sampler for monitoring dioxin-contaminated surface and ground waters. It consists of an alumina cylinder lined with a thin coating of titania and...

متن کامل

Determination of PCDD/Fs, PBDD/Fs and dioxin-like PCBs in human milk from mothers residing in the rural areas in Flanders, using the CALUX bioassay and GC-HRMS.

Since the CALUX (Chemically Activated LUciferase gene eXpression) bioassay is a fast and inexpensive tool for the determination of dioxin-like compounds in a large number of samples and requires only small sample volumes, the use of this technique in human biomonitoring programs provides a good alternative to GC-HRMS. In this study, a new CALUX method for the separate analysis of PCDD/Fs and di...

متن کامل

Bio/chemical analysis of dioxin-like compounds in sediment samples from Osaka Bay, Japan.

The combinatorial bio/chemical investigation of sediments (six surface samples and one core sample) from Osaka Bay, Japan was conducted to clarify the horizontal and vertical distribution profiles of persistent organic pollutants in the sediments. Concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), polychlorinated biphenyls (PCBs), polybrominated dibenzo-p-dioxins a...

متن کامل

Thermodynamics Study of Polychlorinated Biphenyls (PCBs) Passing through SWNT and Their Removal from Environment

Polychlorinated Biphenyls (PCBs) have been widely used to flame-retard products common in homes and theworkplace, and subsequently. Polychlorinated biphenyls (PCBs) typify a class of highly toxic, stable aromaticpollutants. PCBs are recently being scrutinized for potential environment damage in groundwater and in theatmosphere. The elimination of chemical pollutants from a contaminated environm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 120  شماره 

صفحات  -

تاریخ انتشار 2014