Angiographic CT in cerebrovascular stenting.
نویسندگان
چکیده
We evaluated the feasibility of angiographic CT (ACT) for visualizing metallic stents in three patients who underwent intracranial (n = 2) or extracranial (n = 1) stent placement to treat atherosclerotic lesions. ACT is a new technique that provides cross-sectional CT-like images based on rotational radiography performed with a rotating C-arm-mounted flat-panel detector. ACT allowed for the clear visualization of stents in both intracranial and extracranial arteries and was superior to conventional digital subtraction angiography and digital radiography in visualizing both the stent struts and their relationships to the arterial walls and aneurysmal lumen.
منابع مشابه
Safety, Efficacy and Clinical Outcome of Direct Stent Implantation
Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...
متن کاملCarotid angioplasty and stenting in a patient with high grade stenosis of Internal Carotid Artery associated with both vertebral arteries and contralateral carotid occlusion
Severe internal carotid artery (ICA) stenosis is a common cause of cerebrovascular accident (CVA) in middle-aged patients. Contralateral carotid occlusion (CCO) in patients with severe ICA stenosis is associated with high risk of CVA. Carotid endarterectomy (CEA) is associated with more complications in patients with CCO than those without CCO. In this study, we present the case of a 61-year-ol...
متن کاملDetection of intracranial in-stent restenosis using quantitative magnetic resonance angiography.
BACKGROUND AND PURPOSE In-stent restenosis (ISR) after angioplasty/stenting for intracranial stenosis has been reported in up to 25% to 30% of patients. Detection and monitoring of ISR relies primarily on serial catheter angiography, because noninvasive imaging methods are typically hampered by stent-related artifact. We examined the value of serial vessel flow measurements using quantitative m...
متن کاملQuantitative cerebrovascular reserve measured by acetazolamide-challenged dynamic CT perfusion in ischemic adult Moyamoya disease: initial experience with angiographic correlation.
BACKGROUND AND PURPOSE CT perfusion is a much more readily accessible imaging method to assess cerebral hemodynamic status than single-photon emission CT. We prospectively assessed quantitative cerebrovascular reserve by using acetazolamide (ACZ)-challenged CT perfusion for evaluating hemodynamic impairment in ischemic adult Moyamoya disease and compared it with angiographic findings. MATERIA...
متن کاملVertebral Stenting and Vertebroplasty Guided by an Angiographic 3D Rotational Unit
Introduction. Use of interventional imaging systems in minimally invasion procedures such as kyphoplasty and vertebroplasty gives the advantage of high-resolution images, various zoom levels, different working angles, and intraprocedure image processing such as three-dimensional reconstructions to minimize complication rate. Due to the recent technological improvement of rotational angiographic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 26 7 شماره
صفحات -
تاریخ انتشار 2005