Pilot investigation of photoplethysmographic signals and blood oxygen saturation values during blood pressure cuff-induced hypoperfusion
نویسنده
چکیده
Photoplethysmography (PPG) is a non-invasive electro-optical technique widely used in the monitoring of the pulsations associated with changes in blood volume in a peripheral vascular bed. The technique is based on the absorption properties of vascular tissue when it is transilluminated by light. Photoplethysmography is also used in the estimation of arterial blood oxygen saturation ðSpO2Þ by pulse oximetry where the technique relies on the presence of adequate peripheral arterial pulsations. The aim of this study was to investigate (14 healthy volunteers) the effect of pressure cuff-induced hypoperfusion on PPG signals and SpO2s using a custommade finger blood oxygen saturation PPG=SpO2 sensor and a commercial finger pulse oximeter. PPG signals with high signal-to-noise ratios were obtained from all induced pressures prior to full brachial occlusion. An Analysis of Variance (ANOVA) on ranks showed that there are statistically significant differences ðp < 0:05Þ between the PPGs in the low pressures (0–80 mmHg) than those in the upper pressures (90–150 mmHg). Both pulse oximeters showed gradual decrease of saturations during induced hypoperfusion which demonstrate the direct relation between blood volumes (PPG amplitudes), arterial vessel stenosis and blood oxygen saturation. The custom made pulse oximeter was found to be more sensitive to SpO2 changes than the commercial pulse oximeter especially at high occluding pressures.
منابع مشابه
INVESTIGATION OF PHOTOPLETHYSMMOGRAPHIC SIGNALS AND ARTERIAL BLOOD OXYGEN SATURATION VALUES (SpO2) DURING BLOOD PRESSURE CUFF-INDUCED HYPOPERFUSION
Photoplethysmography is a non-invasive electro-optical technique widely used in the study and monitoring of the pulsations associated with changes in blood volume in a peripheral vascular bed. Photoplethysmography is used in the estimation of arterial oxygen saturation (SpO2) by pulse oximetry. A reflectance finger photoplethysmographic (PPG) probe and a multiplexed data acquisition system oper...
متن کاملArterial Blood Oxygen Saturation during Blood Pressure Cuff-induced Hypoperfusion
Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO2) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vaso...
متن کاملAutomatic noninvasive measurement of systolic blood pressure using photoplethysmography
BACKGROUND Automatic measurement of arterial blood pressure is important, but the available commercial automatic blood pressure meters, mostly based on oscillometry, are of low accuracy. METHODS In this study, we present a cuff-based technique for automatic measurement of systolic blood pressure, based on photoplethysmographic signals measured simultaneously in fingers of both hands. After in...
متن کاملAn in vivo investigation of photoplethysmographic signals and preliminary pulse oximetry estimation from the bowel using a new fiberoptic sensor.
BACKGROUND The continuous monitoring of splanchnic organ oxygen saturation could make the early detection of inadequate tissue oxygenation feasible, reducing the risk of hypoperfusion, severe ischemia, multiple organ failure, and, ultimately, death. Current methods for assessing splanchnic perfusion have not been widely accepted for use in the clinical care environment. In an attempt to overcom...
متن کاملInvestigation of oesophageal photoplethysmographic signals and blood oxygen saturation measurements in cardiothoracic surgery patients.
Pulse oximeter probes attached to the finger may fail to estimate blood oxygen saturation (SpO2) in patients with compromised peripheral perfusion (e.g. hypothermic cardiopulmonary bypass surgery). The measurement of SpO2 from a central organ such as the oesophagus is suggested as an alternative to overcome this problem. A reflectance oesophageal pulse oximeter probe and a processing system imp...