© 2016, IRJET | Impact Factor value: 4.45 | ISO 9001:2008 Certified Journal | Page 1049 PERFORMANCE EVALUATION OF DIFFERENTIAL BIO-POTENTIAL AMPLIFIER Prerna Mittal1, Padma Batra2 1M-Tech Degree in Electronics and Communication, Krishna Institute of Engineering and Technology, Ghaziabad, UPTU, India 2 Associate Professor, EC Department, Krishna Institute of Engineering and Technology, Ghaziabad, UPTU, India ---------------------------------------------------------------------***--------------------------------------------------------------------Abstract-Differential Bio-potential Amplifier is used to measuring the bio-impedance of the living things, like human body. The value of bio-impedance of body is very low on scale. To enhance it in a readable for this amplifier is used. It increases the value tobio-impedance up to very high on a scale. So measurement of bio-impedance correctly is a difficult task. It requires very precision circuitry to calculate it and enhance it. The performance of existing current driving circuits was also analyzed. Measured data showed that they failed to achieve desired specifications as one or the other parameters did not matched according to requirement. This was due to different component gain achievement .Most of these limitations might be reduced as has been done in this research. In applications where highly précised amplifier with high input impedance and CMRR is required, this proposed circuit can be used. In this research work, we have explained that how the performance parameters and correct choice of components required to meet the high input impedance and CMRR of a circuit. An approach of using TLV2474 op-amp in place of conventionally usedop-amp. In proposed circuit has been shown to have better performance than all other input impedance & CMRR used in past research works. A complete circuit analysis for input impedance and CMRR is performed using MULTISIM software developed by national instruments under wide range of components different-different values.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Low Power Low Voltage Rail to Rail Constant gm Differential Amplifier with 150 dB CMRR and Enhanced Frequency Performance

This paper proposes a low voltage (±0.55V supply voltage) low power (44.65µW) high common mode rejection ratio (CMRR) differential amplifier (d.a.) with rail to rail input common mode range (ICMR), constant transconductance (gm) and enhanced frequency performance. Its high performance is obtained using a simple negative averaging method so that it cancels out the common mode input signals at th...

متن کامل

Indigenous Design of Electronic Circuit for Electrocardiograph

This paper provides electronic implementation of electrocardiograph (ECG) circuit by using instrumentation amplifier (IA) as bio-potential amplifier in such a manner which reduces noise, common voltage, DC offset value and RF interference from the existing circuit.Noise and common voltage can be removed from ECG using driven right leg circuit or by using isolator circuit. DC offset can be remov...

متن کامل

An Ultra High CMRR Low Voltage Low Power Fully Differential Current Operational Amplifier (COA)

this paper presents a novel fully differential (FD) ultra high common mode rejection ratio (CMRR) current operational amplifier (COA) with very low input impedance. Its FD structure that attenuates common mode signals over all stages grants ultra high CMRR and power supply rejection ratio (PSRR) that makes it suitable for mixed mode and accurate applications. Its performance is verified by HSPI...

متن کامل

Relative Measurement of Differential Electrode Impedance for Contact Monitoring in a Biopotential Amplifier 601 Relative Measurement of Differential Electrode Impedance for Contact Monitoring in a Biopotential Amplifier

In this paper, we propose a simple and relative electrode contact monitoring method. By exploiting the power line interference, which is regarded as one of the worst noise sources for bio-potential measurement, the relative difference in electrode impedance can be measured without a current or voltage source. Substantial benefits, including no extra circuit components, no degradation of the bod...

متن کامل

A Power-Efficient Bio-Potential Acquisition Device with DS-MDE Sensors for Long-Term Healthcare Monitoring Applications

This work describes a power-efficient bio-potential acquisition device for long-term healthcare applications that is implemented using novel microelectromechanical dry electrodes (MDE) and a low power bio-potential processing chip. Using micromachining technology, an attempt is also made to enhance the sensing reliability and stability by fabricating a diamond-shaped MDE (DS-MDE) that has a sat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017