The impact of environmental factors in pre-hospital thermistor-based tympanic temperature measurement: a pilot field study

نویسندگان

  • Sven Christjar Skaiaa
  • Guttorm Brattebø
  • Jörg Aßmus
  • Øyvind Thomassen
چکیده

BACKGROUND Few pre-hospital services have the possibility to accurately measure core temperature (T core). Non-invasive estimation of T core will improve pre-hospital decision-making regarding the triage and management of hypothermic patients. Thermistor-based tympanic temperature (T tymp) correlates well with T core in controlled studies; however, little is known about the feasibility of using T tymp under field conditions. This study assessed the impact of pre-hospital environmental factors on the accuracy of T tymp . Deep rectal temperature (T rect) was used as a substitute for T core . METHODS Normothermic volunteers (n = 13) were exposed to four simulated field conditions producing local cooling of the head and ear canal. After exposure, T tymp was recorded every 15 s for 10 min and compared with T rect . Descriptive analysis and Bland-Altman plots were used to assess agreement. RESULTS Immediately after exposure mean T tymp was low, but increased rapidly and reached an apparent steady state after 3-5 min. After 5 and 10 min, the mean temperature difference (∆T rect-tymp) ranged from 1.5-3.2 °C (SD = 0.5) and 1.2-2.0 °C, respectively. T rect remained unchanged throughout the study period. CONCLUSIONS After surface cooling of head and neck, T tymp did not accurately reflect core temperature within the first 10 min of measurement. The variation of ∆T rect-tymp was low after 10 min, regardless of the initial degree of cooling. With the risk of over-triage, T tymp may at this point provide an indication of T core and also exhibit a trend. TRIAL REGISTRATION ClinicalTrials.gov: NCT02274597.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Structure for Direct Measurement of Temperature Based on Negative Temperature Coefficient Thermistor and Adaptive Neuro-fuzzy Inference System

Thermistors are very commonly used for narrow temperature-range high-resolution applications, such as in medicine, calorimetry, and near ambient temperature measurements. In particular, Negative Temperature Coefficient (NTC) thermistor is very inexpensive and highly sensitive, whose sensing temperature range and sensitivity are highly limited due to the intrinsic nonlinearity and self-heating p...

متن کامل

An evaluation of infra-red tympanic thermometry for thermal physiology research.

This study forms part of a research programme to investigate the relationships between the rise in core temperature and the environmental temperature in soldiers exercising at a constant rate. The measurement of core temperature is a fundamental requirement for this research. The aim of this study was to evaluate the use of an infra-red tympanic thermometer (IVAC Corecheck) for use in thermal p...

متن کامل

Non-invasive Measures of Core Temperature versus Ingestible Thermistor during Exercise in the Heat

The accuracy of core temperature (Tc) thermometry from temporal, tympanic, and oral thermometry devices has been variable during exercise in a hot, humid environment. The purpose of the present study was to cross-validate temporal, two tympanic devices, and oral devices compared to an ingestible thermistor during exercise in a hot, humid environment. Fourteen young, active adults (6 women) comp...

متن کامل

بررسی صحت و دقت دمای تمپانیک در بازتاب دمای مرکزی بدن

  Background & Aim: Monitoring of patients' temperature is an important nursing clinical procedure. Body temperature is usually taken at different sites including pulmonary artery, rectal, oral, and axillary areas. Currently, infrared tympanic temperature measurement method is increasingly used as a convenient, noninvasive and rapid method. However, accuracy and precision of this method has bee...

متن کامل

Investigation of the compatibility of wet bulb globe temperature (WBGT) and predicted heat strain (PHS) in assessing the environmental conditions and heat load imposed on individuals: a case study in bakery workers

Introduction: This study was designed with the main purpose of examining the compatibility of the two indicators of wet bulb globe temperature (WBGT) and predicted thermal strain (PHS) in assessing the environmental conditions and the heat load imposed on the subjects. Method: In this cross-sectional study, 163 bakers were included in the study. Thermal stress was determined using the WBGT and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 23  شماره 

صفحات  -

تاریخ انتشار 2015