Controlled evaluation of the agar-slide and radiometric blood culture systems for the detection of bacteremia and fungemia.

نویسندگان

  • M P Weinstein
  • L B Reller
  • S Mirrett
  • C W Stratton
  • L G Reimer
  • W L Wang
چکیده

A commercially available agar-slide blood culture bottle (Septi-Chek; Roche Diagnostics, Div. Hoffman-La Roche, Inc., Nutley, N.J.) was compared with the radiometric blood culture system (BACTEC; Johnston Laboratories, Inc., Towson, Md.) in 8,544 paired blood cultures from adult patients. The systems were inoculated with equal volumes (10 ml) of blood. Overall, there was no statistically significant difference between the two systems in the recovery of clinically important microorganisms, but significantly more members of the family Enterobacteriaceae other than Escherichia coli were detected by the agar-slide system (P less than 0.005). The agar-slide system detected more fungi, and the BACTEC detected more anaerobic bacteria; however, small numbers of recovered organisms precluded statistical significance. When microorganisms grew in both systems, their presence was detected one or more days earlier in the BACTEC (P less than 0.001). More contaminants grew in the agar-slide system (P less than 0.001). Both systems performed well, and either system should provide high yield and prompt detection of positive blood cultures in patients with bacteremia and fungemia if used in an optimal way as recommended by the respective manufacturers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Controlled comparison of a new Becton Dickinson agar slant blood culture system with Roche Septi-Chek for the detection of bacteremia and fungemia.

Two commercially available agar slide blood culture systems, Septi-Chek (Roche Diagnostics, Div. Hoffmann-La Roche Inc., Nutley, N.J.) and VACUTAINER agar slant (Becton Dickinson [BD] Vacutainer Systems, Rutherford, N.J.), were compared in 5,628 paired blood cultures from adult patients. The systems were inoculated with equal volumes (5 ml) of blood. There was no statistically significant diffe...

متن کامل

Controlled evaluation of supplemented peptone and Bactec blood culture broths for the detection of bacteremia and fungemia.

Comparison of conventional blood culture media with newer formulations of Bactec media for radiometric detection are lacking. Therefore, we compared the yield and speed of detection of clinically important microorganisms with supplemented peptone broth (SPB) and Bactec aerobic (6B) and anaerobic (7C or 7D) broths in 7,627 blood samples from adult patients. Acridine orange stains from SPB, radio...

متن کامل

Evaluation of the blood volume effect on the diagnosis of bacteremia in automated blood culture systems.

BACKGROUND Blood culture volume is the most important variable in detecting bacteremia and fungemia. However, the majority of hospitals in Taiwan do not meet the criteria for an ideal blood culture volume (8-10 mL per bottle, two bottles per set) during collection. METHODS The object of this study is to initiate an educational program for healthcare workers to increase blood volume collection...

متن کامل

Clinical comparison of an agar slide blood culture bottle with tryptic soy broth and a conventional blood culture bottle with supplemented peptone broth.

The Roche Septi-Chek biphasic blood culture system with tryptic soy broth was compared with a conventional blood culture bottle with supplemented peptone broth in 6,956 paired blood cultures from adult patients. Both systems were inoculated with equal volumes of blood (5 ml) and incubated aerobically (vented) for 2 weeks. More clinically important bacteria and fungi, including Staphylococcus au...

متن کامل

Clinical laboratory comparison of the 10-ml isolator blood culture system with BACTEC radiometric blood culture media.

The efficiency of the 10-ml Isolator (E. I. du Pont de Nemours & Co., Inc.) for recovery of pathogens from blood was compared with that of BACTEC 6B and 7C media (Johnston Laboratories) by using 4,195 cultures from 1,662 patients. During the first phase of the study, BACTEC bottles were inoculated with 3 ml of blood; in the second phase, bottles were inoculated with 5 ml. The objectives were to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 23 2  شماره 

صفحات  -

تاریخ انتشار 1986