Self-sensing cantilevers with integrated conductive coaxial tips for high-resolution electrical scanning probe metrology
نویسندگان
چکیده
Study of sensitivity and noise in the piezoelectric self-sensing and self-actuating cantilever with an integrated Wheatstone bridge circuit Rev. Current integration force and displacement self-sensing method for cantilevered piezoelectric actuators Rev. Quasistatic displacement self-sensing method for cantilevered piezoelectric actuators Rev. The lateral resolution of many electrical scanning probe techniques is limited by the spatial extent of the electrostatic potential profiles produced by their probes. Conventional unshielded conductive atomic force microscopy probes produce broad potential profiles. Shielded probes could offer higher resolution and easier data interpretation in the study of nanostructures. Electrical scanning probe techniques require a method of locating structures of interest, often by mapping surface topography. As the samples studied with these techniques are often photosensitive, the typical laser measurement of cantilever deflection can excite the sample, causing undesirable changes electrical properties. In this work, we present the design, fabrication, and characterization of probes that integrate coaxial tips for spatially sharp potential profiles with piezoresistors for self-contained, electrical displacement sensing. With the apex 100 nm above the sample surface, the electrostatic potential profile produced by our coaxial tips is more than 2 times narrower than that of unshielded tips with no long tails. In a scan bandwidth of 1 Hz–10 kHz, our probes have a displacement resolution of 2.9 A ˚ at 293 K and 79 A ˚ at 2 K, where the low-temperature performance is limited by amplifier noise. We show scanning gate microscopy images of a quantum point contact obtained with our probes, highlighting the improvement to lateral resolution resulting from the coaxial tip.
منابع مشابه
A scanning probe microscope for magnetoresistive cantilevers utilizing a nested scanner design for large-area scans
We describe an atomic force microscope (AFM) for the characterization of self-sensing tunneling magnetoresistive (TMR) cantilevers. Furthermore, we achieve a large scan-range with a nested scanner design of two independent piezo scanners: a small high resolution scanner with a scan range of 5 × 5 × 5 μm(3) is mounted on a large-area scanner with a scan range of 800 × 800 × 35 μm(3). In order to...
متن کاملUltra-sensitive NEMS-based cantilevers for sensing, scanned probe and very high-frequency applications.
Scanning probe microscopies (SPM) and cantilever-based sensors generally use low-frequency mechanical devices of microscale dimensions or larger. Almost universally, off-chip methods are used to sense displacement in these devices, but this approach is not suitable for nanoscale devices. Nanoscale mechanical sensors offer a greatly enhanced performance that is unattainable with microscale devic...
متن کاملScanning probe microscopy based on magnetoresistive sensing.
Integrated sensors are essential for scanning probe microscopy (SPM) based systems that employ arrays of microcantilevers for high throughput. Common integrated sensors, such as piezoresistive, piezoelectric, capacitive and thermoelectric sensors, suffer from low bandwidth and/or low resolution. In this paper, a novel magnetoresistive-sensor-based scanning probe microscopy (MR-SPM) technique is...
متن کاملUltrananocrystalline diamond tip integrated onto a heated atomic force microscope cantilever.
We report a wear-resistant ultrananocrystalline (UNCD) diamond tip integrated onto a heated atomic force microscope (AFM) cantilever and UNCD tips integrated into arrays of heated AFM cantilevers. The UNCD tips are batch-fabricated and have apex radii of approximately 10 nm and heights up to 7 μm. The solid-state heater can reach temperatures above 600 °C and is also a resistive temperature sen...
متن کاملSilicon cantilevers and tips for scanning force microscopy*
Monocrystallme slhcon canttlevers with Integrated sdlcon tips for scannmg force mlcroscopy are fabncated by means of mlcromachmmg techmques Theorettcal conslderatlons mcludmg fimte element modelhng have been carried out m order to find a smtable shape and dlmenslons according to the mechanical requirements Several different cantilever designs have been fabricated a simple beam with various cros...
متن کامل