Electrical equivalence of electrospray ionization with conducting and nonconducting needles.

نویسندگان

  • G S Jackson
  • C G Enke
چکیده

An electrical equivalent circuit is derived for the electrospray process. It is a series circuit which consists of the power supply, the electrochemical contact to the solution, the solution resistance (R(s)), a constant-current regulator which represents the processes of charge separation and charge transport in the gap between the spray needle aperture and the counter electrode, and charge neutralization at the counter electrode. A current i, established by the constant-current regulator flows throughout the entire circuit. Current-voltage curves are developed for each element in the circuit. From these it is shown that in the case where R(s) is negligible (the power supply is connected directly to a conducting needle) the shape of the current-voltage curve is dictated by the constant-current regulator established by the charge separation process, the gap, and the counter electrode. The solution resistance may be significant if a nonconducting needle is used so that the electrochemical contact to the solution is remote from the tip. Experiments with a nonconducting spray needle quantify the effect of the solution resistance on the current-voltage curve. Subtracting the iRs voltage from Vapp (power supply voltage) yields the current-voltage curve for the constant-current regulator. When iRs drop is a significant fraction of Vapp, the current-voltage curve of the constant-current regulator is changed substantially from the case when the solution resistance is negligible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

Quantification of Melittin in Iranian Honey Bee (Apis mellifera meda) Venom by Liquid Chromatography-electrospray Ionization-ion Trap Tandem Mass Spectrometry (LC-ESI-IT-MS/MS)

The current research aimed to quantify melittin (MEL) in Iranian honey bee (Apis mellifera meda) venom. To this end, a liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (LC-ESI-IT-MS/MS) approach was employed. Melittin is the main toxic peptide of honey bee venom with various biological and pharmacological activities. It was extracted with...

متن کامل

Subproblem h-Conform Formulation for Accurate Thin Shell Models Between Conducting and Nonconducting Regions

Models Between Conducting and Nonconducting Regions Vuong Q. Dang, Patrick Dular, Ruth V. Sabariego, Laurent Krähenbühl, and Christophe Geuzaine 1 University of Liège, Dept. of Electrical Engineering and Computer Science, ACE, B-4000 Liège, Belgium 2 Fonds de la Recherche Scientifique F.R.S.-FNRS, Belgium 3 Université de Lyon, Ampère (CNRS UMR5005), École Centrale de Lyon, F-69134 Écully, Franc...

متن کامل

A conductive polymeric material used for nanospray needle and low-flow sheathless electrospray ionization applications.

A conductive polypropylene/graphite mixture is used for the production of polymeric nanospray needle emitters and as a coating on fused-silica capillaries that are used for sheathless electrospray ionization (ESI). The described production of these polymeric nanospray needle emitters and sheathless ESI contacts is exceptionally easy and at a very low cost. The described polymeric nanospray emit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 71 17  شماره 

صفحات  -

تاریخ انتشار 1999