A new noninvasive method to measure blood pressure: results of a multicenter trial.

نویسندگان

  • K Belani
  • M Ozaki
  • J Hynson
  • T Hartmann
  • H Reyford
  • J M Martino
  • M Poliac
  • R Miller
چکیده

BACKGROUND Blood pressure (BP) monitoring with arterial waveform display requires an arterial cannula. We evaluated a new noninvasive device, Vasotrac (Medwave, Arden Hills, MN) that provides BP measurements approximately every 12-15 beats and displays pulse rate and a calibrated arterial waveform for each BP measurement. METHODS Surgical and critically ill patients (n = 80) served as subjects for the study. BPs, pulse waveforms, and pulse rates measured via a radial artery catheter were compared with those obtained by the Vasotrac from the opposite radial artery. Data were analyzed to determine agreement between the two systems of measurement. RESULTS Blood pressure measured noninvasively by the Vasotrac demonstrated excellent correlation (P<0.01) with BP measured via a radial arterial catheter (systolic r2 = 0.93; diastolic r2 = 0.89; mean r2 = 0.95). Differences in BP measured by the Vasotrac versus the radial arterial catheter were small. The mean+/-SD bias and precision were as follows: systolic BP 0.02+/-5.4 mm Hg and 3.9+/-3.7 mm Hg; diastolic BP -0.39+/-3.9 mm Hg and 2.7+/-2.8 mm Hg; mean BP -0.21+/-3.0 mm Hg and 2.1+/-2.2 mm Hg compared with radial artery measurements. The Vasotrac pulse rates were almost identical to those measured directly (r2 = 0.95). The Vasotrac BP waveform resembled those directly obtained radial artery pulsatile waveforms. CONCLUSIONS In surgical and critically ill patients, the Vasotrac measured BP, pulse rate, and displayed radial artery waveform, which was similar to direct radial arterial measurements. It should be a suitable device to measure BP frequently in a noninvasive fashion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تخمین بدون کاف فشارخون مبتنی بر ویژگی‌های زمانی سیگنال نبض

Blood pressure is one of the vital signs. Specially, it is crucial for some cases such as hypertension patients and it should be monitored continuously in ICU/CCU. It must be noted that current systems to measure blood pressure, often require trained operators. As an example, in post-hospital cares, blood pressure control is difficult except with the presence of a nurse or use of a device that ...

متن کامل

Comparison of Various Blood Pressure Measurement Techniques with Standard Office Based Blood Pressure Mesurement

Introduction: In order to control Hypertension, it is necessary to understand the methods of blood pressure measurement. Recent guidelines emphasize on employing appropriate blood pressure measurement techniques and white coat hypertension. Definition and methods of blood pressure measurement have changed in the American guideline based on SPRINT trial (Systolic Blood Pressure Intervention Tria...

متن کامل

Comparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study

Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...

متن کامل

Continuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals By Using Microsoft Visual C Sharp

Background: One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff.Objective: In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference ...

متن کامل

Designing and Constructing an Optical System to measure Continuous and Cuffless Blood Pressure Using Two Pulse Signals

Introduction Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure is estimated from pulse transit time (PTT). This study uses two pulse sensors to get PTT. The aim of this study was to construct an optical system and to monitor blood pressure continuously and without cuff in people with different ages. Materials and M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 91 3  شماره 

صفحات  -

تاریخ انتشار 1999