Calibration of ac and dc magnetometers with a Dy2O3 standard.
نویسندگان
چکیده
The ac susceptibility and magnetization curves of a glued Dy(2)O(3) powder sample are measured by an ac susceptometer and a dc superconducting quantum interference device magnetometer, both of which have been calibrated previously. It is shown that the magnetic moment of the paramagnetic sample as a function of field and temperature may be accurately expressed by a combination of the Curie-Weiss law and the Langevin function at T > 45 K with three adjusting parameters, so that the dc magnetization curves and the magnitude and phase of ac susceptibility at different values of dc bias field measured by any magnetometer can be calibrated by using Dy(2)O(3) as a standard. The expressions are empirical and cannot be justified in the entire field and temperature range by existing theories of paramagnetism. Below 10 K, indication of approaching a possible phase transition is found. It is shown that pure Dy(2)O(3) powder may be used as a primary standard, with susceptibility [13.28(T + 17)](-1) emu/Oe/g at T > 50 K and H < 10 kOe, in consistency with the Curie-Weiss law and the quantum mechanical theory of paramagnetism.
منابع مشابه
Magnetic Calibration of Three-Axis Strapdown Magnetometers for Applications in Mems Attitude-Heading Reference Systems
In a strapdown magnetic compass, heading angle is estimated using the Earth's magnetic field measured by Three-Axis Magnetometers (TAM). However, due to several inevitable errors in the magnetic system, such as sensitivity errors, non-orthogonal and misalignment errors, hard iron and soft iron errors, measurement noises and local magnetic fields, there are large error between the magnetometers'...
متن کاملReal Time Calibration of Strap-down Three-Axis-Magnetometer for Attitude Estimation
Three-axis-magnetometers (TAMs) are widely utilized as a key component of attitude determination subsystems and as such are considered the corner stone of navigation for low Earth orbiting (LEO) space systems. Precise geomagnetic-based navigation demands accurate calibration of the magnetometers. In this regard, a complete online calibration process of TAM is developed in the current research t...
متن کاملAC-DC Transfer Standard Measurements Using An AC Josephson Voltage Standard
NIST is implementing the Josephson arbitrary waveform synthesizer as an ac Josephson Voltage Standard (ACJVS). Over the past few years we have demonstrated precise measurements of synthesized sine waves at rms voltage amplitudes up to 170 mV. The system can generate a variety of precision voltage outputs including dc voltages and ac sinewaves, so it can be used as a quantum-based voltage source...
متن کاملThe FIELDS Instrument Suite on MMS: Scientific Objectives, Measurements, and Data Products
The FIELDS instrumentation suite on the Magnetospheric Multiscale (MMS) mission provides comprehensive measurements of the full vector magnetic and electric fields in the reconnection regions investigated by MMS, including the dayside magnetopause and the night-side magnetotail acceleration regions out to 25 Re. Six sensors on each of the four MMS spacecraft provide overlapping measurements of ...
متن کاملExtension of the NIST AC-DC Difference Calibration Service for Current to 100 kHz
The NIST calibration service for ac-dc difference of thermal current converters relies on multijunction thermal converters as the primary standards, and various thermal converters and thermoelements (TEs) as the reference and working standards. Calibrations are performed by comparing the ac-dc difference of a customer's thermal current converter to the ac-dc difference of a NIST standard curren...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 82 4 شماره
صفحات -
تاریخ انتشار 2011