Shear wave elastography of placenta: in vivo quantitation of placental elasticity in preeclampsia.
نویسندگان
چکیده
PURPOSE We aimed to evaluate the utility of shear wave elastography (SWE) for assessing the placenta in preeclampsia disease. METHODS A total of 50 pregnant women in the second or third trimester (23 preeclampsia patients and 27 healthy control subjects) were enrolled in the study. Obstetrical grayscale and Doppler ultrasonography, SWE findings of placenta, and prenatal/postnatal clinical data were analyzed and the best SWE cutoff value which represents the diagnosis of preeclampsia was determined. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of preeclampsia were calculated based on SWE measurements. RESULTS Mean stiffness values were much higher in preeclamptic placentas in all regions and layers than in normal controls. The most significant difference was observed in the central placental area facing the fetus where the umbilical cord inserts, with a median of 21 kPa (range, 3-71 kPa) for preeclampsia and 4 kPa (range, 1.5-14 kPa) for the control group (P < 0.01). The SWE data showed a moderate correlation with the uterine artery resistivity and pulsatility indices. The cutoff value maximizing the accuracy of diagnosis was 7.35 kPa (area under curve, 0.895; 95% confidence interval, 0.791-0.998); sensitivity, specificity, PPV, NPV, and accuracy were 90%, 86%, 82%, 92%, and 88%, respectively. CONCLUSION Stiffness of the placenta is significantly higher in patients with preeclampsia. SWE appears to be an assistive diagnostic technique for placenta evaluation in preeclampsia.
منابع مشابه
Shear Wave Elastography in the Living, Perfused, Post-Delivery Placenta.
The placenta is the critical interface between the mother and the developing fetus and is essential for survival and growth. Despite the widespread use of ultrasound imaging and Doppler in obstetrics and gynecology and the recent growth of elastographic technologies, little is known about the biomechanical (elastic shear wave) properties of the placenta and the range of normal and pathologic pa...
متن کاملEvaluation of the diagnostic function of shear wave elastography in the differentiation of malignant and benign breast masses and its relationship with histological factors
Background: Shear wave elastography (SWE) estimates the stiffness of a mass based on the velocity of shear wave propagation by sound waves. Due to higher cell density and angiogenesis, malignant masses have higher stiffness than benign ones. Methods: The present study was a prospective study and was performed on patients who were referred to Ahvaz Golestan Hospital with breast mass during Marc...
متن کاملProstate MRE at 3T: Trans-perineal wave propagation
Introduction There has been a great interest in applying Magnetic Resonance Elastography (MRE) to quantify the visco-elastic properties of the prostate in-vivo, with the goal of imaging prostate cancer. Current MRE methods [1-3] have limitations with acquiring high-SNR motion encoded MR-signals at 1.5T, and inducing shear waves of sufficient amplitude into the prostate reliably and in a patient...
متن کاملQuantifying the passive stretching response of human tibialis anterior muscle using shear wave elastography.
BACKGROUND Quantifying passive stretching responses of individual muscles helps the diagnosis of muscle disorders and aids the evaluation of surgical/rehabilitation treatments. Utilizing an animal model, we demonstrated that shear elastic modulus measured by supersonic shear wave elastography increases linearly with passive muscle force. This study aimed to use this state-of-the-art technology ...
متن کاملEffect of renal perfusion and structural heterogeneity on shear wave elastography of the kidney: an in vivo and ex vivo study
BACKGROUND To evaluate the effect of perfusion status on elasticity measurements of different compartments in the kidney using shear wave elastography (SWE) both in vivo and ex vivo. METHODS Thirty-two rabbit kidneys were used to observe the elasticity variation caused by renal artery stenosis and vein ligation in vivo, and six beagle kidneys were studied ex vivo to explore the effect of rena...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Diagnostic and interventional radiology
دوره 21 3 شماره
صفحات -
تاریخ انتشار 2015