[Determination of zinc in very small body hair samples by one-drop flame atomic absorption spectrophotometry].

نویسندگان

  • S Kobayashi
  • J Yamamoto
  • Y Kaneda
  • K Nishino
  • Y Itokawa
چکیده

A method for determination of zinc contents in very small samples of hair was developed in order to estimate the zinc concentration in the human body. All steps from weighing of samples to ashing and preparation of the test solution were done in a tube designed by us to prevent contamination and to improve handling. Zinc concentration was determined with flame atomic absorption spectrophotometry aspirating a small volume of samples (80 microliters), by the so-called "one-drop method". Using this method, 5 mg of whiskers was analyzed every day for 10 days, and this revealed that the fluctuation of the zinc concentration level was very small and that it was possible to trace the individual level of zinc concentration daily. A sample of 5 mg is enough for the application of this method. Zinc concentration in the hair under the temple of a boy, and even the low-level zinc content of patients receiving total parenteral nutrition could be accurately determined every 10 days and monthly, respectively. The level of hair zinc contents for neonates was similar to that of adults.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dispersive Liquid-Liquid Microextraction Based on Solidification of Floating Organic Drop Combined with Flame Atomic Absorption Spectrometry for Preconcentration and Determination of Thallium(III) in Water Samples

Dispersive Liquid-Liquid MicroExtraction technique based on Solidification of a Floating Organic drop (DLLME-SFO) combined with flame atomic absorption spectrometry was developed for determination of thallium in water sample. An appropriate mixture of acetone and 1-undecanol was rapidly injected into an aqueous sample containing TlCl4- which forms an ion pair with bril...

متن کامل

Sepration and determination trace amount of cadmium ions in real and water samples by cloud point extraction - flame atomic absorption spectrophotometry after preconcentration with non-ionic surfactant Triton-X114

2-(3- indolyl) – 4,5 di phynyl imidazole.(IDPI) was used as a complexing agent in cloud point extraction for the first time and applied for selective pre-concentration of trace amounts of cadmium. The method is based on the extraction of cadmium at pH= 7.0 by using non-ionic surfactant Triton-X114 and 2-(3- indolyl) – 4,5 di phynyl imidazole. (IDPI) as a chelating agent. The adopted concentrati...

متن کامل

Dispersive liquid–liquid microextraction based on solidification of floating organic drop combined with flame atomic absorption spectrometry for determination trace amount of cobalt in water samples

An efficient, rapid, simple, and highly selective dispersive liquid–liquid microextraction basedon solidification of floating organic drop (DLLME-SFOD), combined with flame atomicabsorption spectrometry was developed for preconcentration and determination of trace amountsof cobalt in water samples. In this method, an appropriate mixture of acetone and1-undecanol was injected rapidly into the aq...

متن کامل

Solid phase extraction of zinc with octadecyl silica membrane disks modified by N,N’-disalicylidene-1,2-phenylendiamine and determination by flame atomic absorption spectrometry

A procedure for separation and preconcentration of trace amounts of Zn(II) from aqueous media is proposed. The procedure is based on the adsorption of Zn2+ on octadecyl bonded silica membrane disk modified with N,N’-disalicylidene-1,2-phenylendiamine at pH 7. The retained zinc ions were then stripped from the disk with a minimal amount of 1.5 mol L-1 hydrochloric acid solution as eluent, and de...

متن کامل

High current–density anodic electrodissolution in flow–injection systems for the determination of aluminium, copper and zinc in non–ferroalloys by flame atomic absorption spectrometry

An automatic procedure with a high current-density anodic electrodissolution unit (HDAE) is proposed for the determination of aluminium, copper and zinc in non-ferroalloys by flame atomic absorption spectrometry, based on the direct solid analysis. It consists of solenoid valve-based commutation in a flow-injection system for on-line sample electro-dissolution and calibration with one multi-ele...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nihon eiseigaku zasshi. Japanese journal of hygiene

دوره 46 3  شماره 

صفحات  -

تاریخ انتشار 1991