Quantitative comparison of 3D and 2.5D gamma analysis: introducing gamma angle histograms.

نویسندگان

  • M Al Sa'd
  • J Graham
  • G P Liney
  • C J Moore
چکیده

Comparison of dose distributions using the 3D gamma method is anticipated to provide better indicators for the quality assurance process than the 2.5D (stacked 2D slice-by-slice) gamma calculation, especially for advanced radiotherapy technologies. This study compares the accuracy of the 3D and 2.5D gamma calculation methods. 3D and 2.5D gamma calculations were carried out on four reference/evaluation 3D dose sample pairs. A number of analysis methods were used, including average gamma and gamma volume histograms. We introduce the concept of gamma-angle histograms. Noise sensitivity tests were also performed using two different noise models. The advantage of the 3D gamma method showed up as a higher proportion of points passing the tolerance criteria of 3% dose difference and 3 mm distance-to-agreement (DTA), with considerably lower average gamma values, a lower influence of the DTA criterion, and a higher noise tolerance. The 3D gamma approach is more reliable than the 2.5D approach in terms of providing comprehensive quantitative results, which are needed in quality assurance procedures for advanced radiotherapy methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

مقایسه عملکرد فیلم گف کرومیک EBT3و فانتوم Delta4® در تکنیک IMRT محیط ناهمگن قفسه سینه

Introdution: In advanced radiotherapy techniques such as intensity modulated radiation therapy (IMRT), the quality assurance (QA) is essential. This study aimed to compare the performance between GafchromicTM EBT3 film and Delta4® phantom (2D and 3D) in heterogeneous chest phantom using IMRT technique. Methods: In this experimental study, two IMRT plans (A and B) were prepared for radiothe...

متن کامل

Quantitative Analysis of GABAA Gamma Receptor Subunits in the Developing Embryonic Chick Forebrain

Objective(s) In this study we investigated the expression of GABAA receptor subunits during brain development. These receptors may change in the embryonic chick forebrain. Materials and Methodes The expression levels of four types of GABAA receptor gamma subunits (γ1, γ2, γ3 and γ4) were quantified in the embryonic chick forebrain at 32 hr, 3, 7, 14, and 20 days of incubation and day one aft...

متن کامل

A 3D quantitative evaluation for assessing the changes of treatment planning system and irradiation techniques in radiotherapy

Purpose: This work proposes and compares two 3D global evaluation methods for assessing the alteration of calculated dose distributions when treatment planning system algorithms or irradiation techniques is modified in radiation therapy. Methods: The global analysis is based on gamma index (γ) proposed by Low et al.1 and Chi (χ) index proposed by Bakai et al.2. The γ and χ values are signed in ...

متن کامل

Evaluation of the Effects of Inhomogeneities on Dose Profiles Using Polymer Gel Dosimeter and Monte Carlo Simulation in Gamma Knife

Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 58 8  شماره 

صفحات  -

تاریخ انتشار 2013