Model-Based Dependability Analysis of Programmable Drug Infusion Pumps
نویسندگان
چکیده
Infusion pumps are commonly used in home/hospital care to inject drugs into a patient at programmable rates over time. However, in practice, a combination of faults including software errors, mechanical failures and human error can lead to catastrophic situations, causing death or serious harm to the patient. Dependability analysis techniques such as failure mode effect analysis (FMEA) can be used to predict the worst case outcomes of such faults and facilitate the development of remedies against them. In this paper, we present the use of model-checking to automate the dependability analysis of programmable, real-time medical devices. Our approach uses timed and hybrid automata to model the real-time operation of the medical device and its interactions with the care giver and the patient. Common failure modes arising from device failures and human error are modeled in our framework. Specifically, we use “mistake models” derived from human factor studies to model the effects of mistakes committed by the operator. We present a case-study involving an infusion pump used to manage pain through the infusion of analgesic drugs. The dynamics of analgesic drugs are modeled by empirically validated pharmacokinetic models. Using model checking, our technique can systematically explore numerous combinations of failures and characterize the worse case effects of these failures.
منابع مشابه
An Observational Study of Errors Related to the Preparation and Administration of Medications Given by Infusion Devices in a Teaching Hospital
Since there is no detailed hospital based incident reporting system, this study was designed to evaluate the medication errors associated with infusion pumps in intensive care unit (ICU). The investigation was conducted in a Teaching hospital in the form of a prospective, observational study. A sample size of 43 doses administered to ICU patients was chosen to enable reliable estimate of error ...
متن کاملAn Observational Study of Errors Related to the Preparation and Administration of Medications Given by Infusion Devices in a Teaching Hospital
Since there is no detailed hospital based incident reporting system, this study was designed to evaluate the medication errors associated with infusion pumps in intensive care unit (ICU). The investigation was conducted in a Teaching hospital in the form of a prospective, observational study. A sample size of 43 doses administered to ICU patients was chosen to enable reliable estimate of error ...
متن کاملDrug Delivery: Enabling Technology for Drug Discovery and Development. iPRECIO® Micro Infusion Pump: Programmable, Refillable, and Implantable
Successful drug delivery using implantable pumps may be found in over 12,500 published articles. Their versatility in delivering continuous infusion, intermittent or complex infusion protocols acutely or chronically has made them ubiquitous in drug discovery and basic research. The recent availability of iPRECIO(®), a programmable, refillable, and implantable infusion pump has made it possible ...
متن کاملAn in vivo canine study to assess granulomatous responses in the MedStream Programmable Infusion System (TM) and the SynchroMed II Infusion System®.
OBJECTIVE A rare, but consistently reported complication of intrathecal (IT) delivery of opioids via programmable implantable infusion pumps is aseptic granuloma formation around the tip of the IT catheter. In the current study, the incidence and severity of IT granuloma formation was assessed for the MedStream Programmable Infusion and SynchroMed II Infusion pumps when delivering saline, baclo...
متن کاملEffect of charge on separation of liposomes upon stagnation
Abstract Liposomes are used widely as drug delivery systems in different forms including nanosuspensions, osmotic pumps, infusion pumps and IV injections. Some of these systems (e.g. infusion or osmotic pumps) might stay stagnant for a long time during or before administration, and therefore, might face phase separation. In spite of these, there is no data available about the behavior of lipos...
متن کامل