[Investigation of reduction of exposure dose in digital mammography: relationship between exposure dose and image processing].

نویسندگان

  • Yoshio Fujimura
  • Hikaru Nishiyama
  • Toshinori Masumoto
  • Shingo Kono
  • Yasuko Kitagawa
  • Toshiki Ikeda
  • Takashi Furukawa
  • Takayuki Ishida
چکیده

In digital mammograms, granularity is an important image property for the detection of microcalcifications and masses. Therefore, we investigated the relationship between the conditions of various exposure doses and the detectability of RMI156 phantom images with and without image processing for the reduction of exposure dose. The images are processed with Gaussian filter and unsharp-masking filters to evaluate the effects on image properties by using the digital Wiener spectrum (WS) presampled modulation transfer function (MTF). In addition, observer performance tests for the detectability of microcalcifications and masses are performed. With Gaussian filtering, the WS value decreased to 50% at 2.0 cycles/mm and the detectability score of masses increased 80% and 12%, on 1.34 mGy and 2.62 mGy, respectively (p<0.05). With unsharp-masking (7 x 7 pixels), the MTF value increased to 126% at 2.0 cycles/mm, and the detectability of microcalcification to 32% and 5%, on 1.34 mGy and 5.28 mGy, respectively (p<0.05) compared with the original image. The optimal dose of simulated lesions with unsharp masking became 5.25 mGy. The unsharp masking could reduce 37% of the exposure dose without a loss of detectability of microcalcifications and masses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Influence of Exposure Index on Image Quality and Radiation Dose

Introduction: The introduction of digital radiography has led to a significant problem in terms of dose creep. To address this problem, manufacturers have established a set of exposure indicators (EI) as a feedback mechanism to safeguard against overexposure. The EI is the measure of incident exposure to the detector that is directly proportional to the signal-to-noise...

متن کامل

Breast dose in conventional and digital mamography

Introduction: The amount of doses received in mammography is one of the biggest concerns in the world. According to some statistics, every 12 minutes a woman dies due to breast cancer. Mammography concerned to detect breast cancer at an early stage of the disease as well as for screening, however due to the risk of exposure, the increasingly and widespread use of mammography fo...

متن کامل

Evaluation of the relation between breast glandular absorbed dose and radiographic quality in mammography

Background: Breast is one of the main radiological sensitive organs, hence it is important to evaluate absorbed dose to this organ especially to the glandular parts. It is the aim of this study to measure mean glandular dose and image contrast in terms of different mammographic parameters. Materials and Methods: In this study two mammography machines located at Said-al Shohada (Giotto) ...

متن کامل

مقایسه میزان دز جذبی پستان در دستگاه ماموگرافی معمولی و دیجیتال در شرایط مورد استفاده دستگاه‌ها در تبریز

Background: The amount of doses received in mammography is one of the biggest concerns in the world. According to some statistics, every 12 minutes a woman dies due to breast cancer. Mammography concerned to detect breast cancer at an early stage of the disease as well as for screening, however due to the risk of exposure, the increasingly and widespread use of mammography for breast cancer scr...

متن کامل

Image quality assessment in digital radiography systems- A Pehamed FLUORAD A+D phantom study

Introduction: The use of digital radiography systems has become more common all around the world. Ideal situation in radiography is to maximize the image quality while minimizing the patient dose. The purpose of this study was to compare image quality and radiation dose in different digital radiography systems. Materials and Methods: Images of Pehamed FLUORAD ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nihon Hoshasen Gijutsu Gakkai zasshi

دوره 64 2  شماره 

صفحات  -

تاریخ انتشار 2008