The Effects of Stationary Phases on Retention and Selectivity of Oligonucleotides in IP-RP-HPLC
نویسندگان
چکیده
There is a growing demand for the separation and identification of short nucleic acid fragments, such as oligonucleotides. There were two main goals of the present investigation, namely, evaluation of the impact of stationary phase type and the influence of various ion-pair reagents on the retention behavior of oligonucleotides in ion-pair liquid chromatography. Three types of ion-pair reagents were studied: triethylammonium acetate, dimethylbuthylammonium acetate and mixtures of 1,1,1,3,3,3-hexafluoro-2-propanol and triethylamine. Two novel types of packing materials, namely, cholesterol and alkylamide were used for this purpose for the first time. The results indicate that the mechanism of oligonucleotides retention is determined by the hydrophobicity of ion-pair reagents and polar ligands localized on the surface of stationary phases. Oligonucleotides were most effectively separated with the use of alkylamide and cholesterol packings. These two stationary phases reduce the time of analysis in comparison with the octadecyl packing material. Moreover, separation was achieved under non-denaturating conditions.
منابع مشابه
EFFECTS OF TEMPERATURE AND PERCENTAGE OF ORGANIC MODIFIER ON RETENTION AND SELECTIVITY IN RP-HPLC USING SOLVATION PARAMETER MODEL
Effects of temperature and percentage of organic modifier were studied on retention and selectivity in RP-HPLC using solvation parameter model. The system constants were determined by multiple linear regression analysis from experimental values in the retention factor for a group of different solutes with known descriptors by computer using the program SPSS/PC. The experimental results showed t...
متن کاملPerformance of 2-Amino Tetraphenyl Porphyrin as Stationary Phase in RP-HPLC of Amino Acids
The search for new stationary phases has been one of the predominant concerns in high performance liquid chromatography (HPLC) in order to achieve better resolutions, longer column lives, and reduce the time of analysis. A chromatographic packing for separation of underivatized amino acids (AAs) were prepared by dynamically coating 2-amino tetraphenyl prophyrin (atpp) on a C-18 reversed-pha...
متن کاملRapid Analysis of Glibenclamide Using an Environmentally Benign Stability-Indicating RP-HPLC Method
An environmentally benign RP-HPLC approach for rapid analysis of glibenclamide in pure form, developed nanoemulsion and commercial tablets was developed and validated in present investigation. The green chromatographic identification was performed on Lichrosphere 250 X 4.0 mm RP C8 column having a 5µm packing as a stationary phase using a combination of ethanol: methanol (50:50 % v/v) as a mobi...
متن کاملRapid Analysis of Glibenclamide Using an Environmentally Benign Stability-Indicating RP-HPLC Method
An environmentally benign RP-HPLC approach for rapid analysis of glibenclamide in pure form, developed nanoemulsion and commercial tablets was developed and validated in present investigation. The green chromatographic identification was performed on Lichrosphere 250 X 4.0 mm RP C8 column having a 5µm packing as a stationary phase using a combination of ethanol: methanol (50:50 % v/v) as a mobi...
متن کاملStudy of RP HPLC Retention Behaviours in Analysis of Carotenoids
For determination of selected carotenoids, various types of columns for high-performance liquid chromatography (HPLC) with different properties have been used. The characteristics of the laboratory-used packing material containing monomeric alkyl-bonded phases (C18, C30) and phenyl as well as phenyl-hexyl stationary phases were studied. The retention data of the examined compounds were used to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 77 شماره
صفحات -
تاریخ انتشار 2014