Performance comparison of the BioSys optical assay and the violet red bile agar method for detecting coliforms in food products.

نویسندگان

  • Ruth Firstenberg-Eden
  • Debra Foti
  • Susan McDougal
  • Stephen Beck
چکیده

Coliform counts in a variety of foods, including dairy products (raw milk, pasteurized milk, yogurt, butter, and ice cream), meats (pork sausage, ground beef, and raw chicken), raw eggs, and chocolate, were performed by the rapid automated BioSys optical assay and the conventional method with violet red bile agar (VRBA). The standard deviation (SD) among five replicate counts for the optical assay was similar to or better than that obtained with VRBA plates for all foods tested. The average SD for all foods tested was 0.21 for the optical assay and 0.30 for the VRBA plates. At very low concentrations of coliforms (1 to 10 CFU/ml for liquid products and 10 to 100 CFU/g for solid samples), the average SDs were 0.26 and 0.47, respectively. The optical assay was less susceptible to interference by noncoliform organisms. In naturally contaminated samples, bacteria such as Serratia liquefaciens, Pantoea spp., Vibrio fluvialis, Aeromonas hydrophilia, and Pseudomonas spp. formed typical colonies in VRBA, resulting in false-positive results or a need to verify colonies in brilliant green lactose broth. The optical assay appeared to be more selective than the VRBA conventional method, detecting fewer noncoliforms. There was close agreement in test results between the two methods, as indicated by correlation coefficients of 0.92 to 0.99 obtained for the regression analysis of the two methods. In most cases both methods distinguished accurately between positive samples containing coliforms and negative controls. All products tested using the automated BioSys Optical Assay for coliforms yielded results more quickly (typically 10 to 12 h) than did those tested with the conventional VRBA method (24 to 72 h with confirmation).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Plating procedure for the enumeration of coliforms from dairy products.

A "repair-detection" procedure consisting of pour plating of food samples with Trypticase soy agar, followed by 1-h repair incubation at room temperature and subsequent overlay with violet red bile agar, was found to be an effective method for the detection of injuried and uninjuried coliforms from dairy products. This method was relatively less effective for the detection of coliforms in many ...

متن کامل

Comparison of fecal coliform agar and violet red bile lactose agar for fecal coliform enumeration in foods.

A 24-h direct plating method for fecal coliform enumeration with a resuscitation step (preincubation for 2 h at 37 +/- 1 degrees C and transfer to 44 +/- 1 degrees C for 22 h) using fecal coliform agar (FCA) was compared with the 24-h standardized violet red bile lactose agar (VRBL) method. FCA and VRBL have equivalent specificities and sensitivities, except for lactose-positive non-fecal colif...

متن کامل

Repair and enumeration of injured coliforms by a plating procedure.

Surface plating of coliforms on Trypticase soy agar, followed by 1 to 2 h of incubation at 25 C and subsequent overlay with violet red bile agar, was found to be a useful method for the repair and enumeration of coliforms injured by freezing.

متن کامل

Comparison of commercially available kits with standard methods for the detection of coliforms and Escherichia coli in foods.

Three commercially available kits that were supplemented with substrates for enzyme reactions were evaluated to determine their abilities to detect coliforms and fecal coliforms in foods. Japanese and U.S. Food and Drug Administration standard methods, as well as two agar plate methods, were compared with the three commercial kits. A total of 50 food samples from various retailers were examined...

متن کامل

Suitability of MRS-bile Agar for the Selective Enumeration of Mixed Probiotic Bacteria in Presence of Mesophilic Lactic Acid Cultures and Yoghurt Bacteria

Measuring the viability of probiotic microorganisms in food products using plate count methodology is a common practice due to the simplicity (ease of performance), inexpensive and routine testing characters ofthis method. In present study, the suitability of de man rogosa and sharpe agar (MRS) bile agar medium forthe selective enumeration of mixed probiotic bacteria (Lactobacillus ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of food protection

دوره 67 12  شماره 

صفحات  -

تاریخ انتشار 2004