Comparison of spin-echo and gradient-echo T1-weighted and spin-echo T2-weighted images at 3T in evaluating term-neonatal myelination.
نویسندگان
چکیده
SUMMARY A prior clinical report of 3T MR imaging in subsequently healthy very premature neonates imaged at term-equivalent age found that both gradient recalled-echo-T1WI and spin-echo-T2WI showed higher rates of myelinated structures, compared with spin-echo-T1WI. The current study set out to assess those rates on the same sequences at 3T in term neonates and thus consisted of 16 term neonates with normal-appearing MR imaging findings who subsequently had normal findings at clinical follow-up. Two neuroradiologists independently assessed 19 structures in those infants on all 3 sequences. Gradient recalled-echo-T1WI showed a slightly higher rate of myelination (57.2%-72.4% of all structures) and interobserver agreement (κ = 0.546, P < .0001) than spin-echo-T2WI (58.2%-64.8%; κ = 0.468, P < .0001), while spin-echo-T1WI had the lowest myelination rate and agreement (25.0%-48.4%; κ = 0.384, P < .0001). Both observers noted that the following structures were myelinated in 88%-100% of patients on gradient recalled-echo-T1WI: the brachium of the inferior colliculus, decussation of the superior cerebellar peduncle, habenular commissure, medial lemniscus, pyramidal decussation, posterior limb of the internal capsule, and superior cerebellar peduncle; on spin-echo-T2WI, there was myelination in 88%-100% of the following structures: the brachium of the inferior colliculus, decussation of the superior cerebellar peduncle, inferior cerebellar peduncle, medial lemniscus, and posterior limb of the internal capsule. In conclusion, this study confirmed that similar to the findings in term-equivalent-age premature infants, myelination changes in term neonates may be best assessed on both gradient recalled-echo-T1WI and spin-echo-T2WI at 3T, and not on spin-echo-T1WI.
منابع مشابه
Comparison of spin-echo T1- and T2-weighted and gradient-echo T1-weighted images at 3T in evaluating very preterm neonates at term-equivalent age.
Term-equivalent imaging can assess myelination status in very preterm infants (<30 weeks' gestational age at birth). However, myelination assessment has yet to be compared among GRE-T1WI, SE-T1WI, and SE-T2WI at 3T. We aimed to compare the rates of myelination among those 3 sequences in 11 very preterm neonates who underwent 3T MR imaging at term-equivalent age and subsequently had normal neuro...
متن کاملGadolinium-DTPA-enhanced MR imaging of spinal neoplasms: preliminary investigation and comparison with unenhanced spin-echo and STIR sequences.
Unenhanced T1- and T2-weighted spin-echo, short inversion time inversion recovery (STIR), and gadolinium-DTPA (Gd-DTPA)-enhanced spin-echo and STIR imaging techniques were used in 20 patients as part of a multicenter study to assess the safety and efficacy of Gd-DTPA in spinal imaging. Five patients had normal MR scans. Of those with lesions, both Gd-DTPA-enhanced T1-weighted spin-echo and unen...
متن کاملComparison of lesion enhancement on spin-echo and gradient-echo images.
PURPOSE To compare lesion enhancement after injection of gadopentetate dimeglumine on spin-echo and gradient-echo T1-weighted images. METHODS A total of 48 contrast-enhancing intracranial lesions were evaluated using a spin-echo and two gradient-echo T1-weighted pulse sequences. Percent contrast, contrast-to-noise, and signal-to-noise measurements were made on the spin-echo T1-weighted, three...
متن کاملMR imaging assessment of myelination in the very preterm brain.
BACKGROUND AND PURPOSE MR imaging was performed in very preterm infants by using an MR imager in the neonatal intensive care unit. The aims of this study were to assess the development of myelination in the preterm brain based on MR imaging findings and to compare the ability of T1-weighted conventional spin-echo, inversion recovery fast spin-echo, and T2-weighted fast spin-echo MR imaging to s...
متن کاملFast multiplanar spoiled gradient-recalled imaging of the liver: pulse sequence optimization and comparison with spin-echo MR imaging.
OBJECTIVE The purpose of this study was to optimize a new rapid-acquisition MR pulse sequence, called fast multiplanar spoiled gradient-recalled (FMPSPGR) imaging, for breath-hold imaging of the liver and to compare unenhanced and contrast-enhanced FMPSPGR with standard spin-echo imaging in detecting liver tumors. MATERIALS AND METHODS The pulse sequence was optimized at 1.5 T with a healthy ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 36 2 شماره
صفحات -
تاریخ انتشار 2015