Central corneal thickness of normal tension glaucoma patients in Japan.

نویسندگان

  • L L Wu
  • Y Suzuki
  • R Ideta
  • M Araie
چکیده

PURPOSE To compare central corneal thickness (CCT) of patients with normal tension glaucoma (NTG) with that of age-matched normal subjects, patients with open-angle glaucoma (POAG) and ocular hypertension (OH) subjects in Japan. METHODS Central corneal thickness was measured in 79 NTG, 61 POAG, 73 OH, and 50 normal subjects with an ultrasonic pachymeter. One eye for 1 subject randomly selected in each group was used for inter-group comparison. The relationship between CCT and the maximum intraocular pressure (IOP) measured by Goldmann applanation tonometer with no ocular hypotensive medication (NTG, OH, and normal subjects) or under medication (POAG patients) was analyzed. RESULTS The CCT of OH subjects (582 +/- 32 microm; mean +/- SD) was significantly greater than that of the other groups (P <.001), while no difference was seen in CCT among normal (552 +/- 36 microm), NTG (548 +/- 33 microm) and POAG (550 +/- 33 microm) subjects. In normal subjects, CCT and the maximum IOP were significantly correlated but the correlation coefficient was small (r = 0.420, P <.05). CONCLUSIONS Central corneal thickness shows no significant difference among NTG, POAG, and normal subjects in Japan, while it is significantly greater in OH subjects. The CCT has little influence on the diagnosis of NTG in Japan.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension.

BACKGROUND/AIMS Recent studies have revealed patients with ocular hypertension to have thicker than normal central corneas and those with normal tension glaucoma to have thinner than normal ones, as determined by ultrasonic pachymetry. Since corneal thickness measurements and applanation tonometric estimates of intraocular pressure (IOP) correlate positively, monitoring of the former parameter ...

متن کامل

Corneal thickness in ocular hypertension, primary open-angle glaucoma, and normal tension glaucoma.

OBJECTIVES To determine the effect of central corneal thickness (CCT) on the measurement of intraocular pressure (IOP) and on the resultant reclassification of patients as having primary open-angle glaucoma (POAG), normal tension glaucoma (NTG), or ocular hypertension (OHT). METHODS Intraocular pressure (Goldmann applanation tonomety) and CCT (ultrasound pachymetry) were measured in 22 patien...

متن کامل

Assessment of corneal biomechanical properties in normal tension glaucoma and comparison with open-angle glaucoma, ocular hypertension, and normal eyes.

PURPOSE To assess the biomechanical properties of corneas in patients with normal tension glaucoma (NTG) and to compare them with those of patients with primary open-angle glaucoma (POAG), ocular hypertension (OHT), and normal controls (N). METHODS Corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann intraocular pressure (IOPg), and corneal compensated IOP (IOPcc) were obtained ...

متن کامل

Central corneal thickness determined with optical coherence tomography in various types of glaucoma.

AIMS To evaluate central corneal thickness determined by optical coherence tomography (OCT) in various types of glaucoma, and its influence on intraocular pressure (IOP) measurement. METHODS Central corneal thickness (CCT) was determined by using OCT in 167 subjects (167 eyes). 20 had primary open angle glaucoma (POAG), 42 had low tension glaucoma (LTG), 22 had ocular hypertension (OHT), 10 h...

متن کامل

Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea

Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Japanese journal of ophthalmology

دوره 44 6  شماره 

صفحات  -

تاریخ انتشار 2000