Electrocoagulation in the treatment of industrial waters and wastewaters

نویسنده

  • Mikko Vepsäläinen
چکیده

Chemical coagulation is commonly used in raw water and wastewater treatment plants for the destabilisation of pollutants so that they can be removed in the subsequent separation processes. The most commonly used coagulation chemicals are aluminium and iron metal salts. Electrocoagulation technology has also been proposed for the treatment of raw waters and wastewaters. With this technology, metal cations are produced on the electrodes via electrolysis and these cations form various hydroxides in the water depending on the water pH. In addition to this main reaction, several side reactions, such as hydrogen bubble formation and the reduction of metals on cathodes, also take place in the cell. In this research, the applications of electrocoagulation were investigated in raw water treatment and wastewater applications. The surface water used in this research contained high concentrations of natural organic matter (NOM). The effect of the main parameters – current density, initial pH, electric charge per volume, temperature and electrolysis cell construction – on NOM removal were investigated. In the wastewater treatment studies, the removal of malodorous sulphides and toxic compounds from the wastewaters and debarking effluents were studied. Also, the main parameters of the treatment, such as initial pH and current density, were investigated. Aluminium electrodes were selected for the raw water treatment, whereas wastewaters and debarking effluent were treated with iron electrodes. According to results of this study, aluminium is more suitable electrode material for electrocoagulation applications because it produces Al(III) species. Metal ions and hydroxides produced by iron electrodes are less effective in the destabilisation of pollutants because iron electrodes produce more soluble and less charged Fe(II) species. However, Fe(II) can be effective in some special applications, such as sulphide removal. The resulting metal concentration is the main parameter affecting destabilisation of pollutants. Current density, treatment time, temperature and electrolysis cell construction affect the dissolution of electrodes and hence also the removal of pollutants. However, it seems that these parameters have minimal significance in the destabilization of the pollutants besides this effect (in the studied range of parameters). Initial pH and final pH have an effect on the dissolution of electrodes, but they also define what aluminium or iron species are formed in the solution and have an effect on the -potential of all charged species in the solution. According to the results of this study, destabilisation mechanisms of pollutants by electrocoagulation and chemical coagulation are similar.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Electrocoagulation and Chemical Coagulation Processes in Removing Reactive red 196 from Aqueous Solution

Background: Conventional chemical coagulation is considered as the old method to color and COD removal in textile effluent. Electrocoagulation (EC) process is a robust method to achieve maximum removal. Methods: This work was designed to compare the result of operational parameters including optimum pH and coagulant concentration for chemical coagulation with ferric chloride and alum. Also, th...

متن کامل

Removal of High Concentrations of Sulfate from Wastewater: Evaluating Different Methods and Proposing the Best Option

Background: Industrial wastewaters containing high amounts of compounds such as sulfate can cause serious risks to human health and environment. Therefore, proposing practical solutions with the lowest cost and the highest efficiency for pollutants removal is of special importance. The purpose of this study is to find a suitable method for treatment wastewater containing very high amounts of...

متن کامل

بررسی عملکرد فرآیند لجن فعال در تصفیه‏ فاضلاب شهرک صنعتی آق‌قلا استان گلستان در سال 1386

Backgrounds and Objectives: One of environmental outcomes in industrial towns is developing environmental pollution such as production of industrial wastewaters. These industrial wastewaters should be appropriately treated before entering to receiving waters. However we can't solve environmental anxieties by establishing of wastewater treatment plants alone but permanent and regular assessment ...

متن کامل

Biological treatability processes of textile wastewaters using electrocoagulation and ozonation

This study presents biotreatment of textile wastewaters using electrocoagulation and ozone processes. Ozonation process gave better results than electrocoagulation process. For electrocoagulation, optimum working conditions were found as follows: pH, 6.5; electrode type, iron electrode; current density, 20 mA/cm2; and reaction time, 15 min. Under these circumstances, values determined for elect...

متن کامل

بررسی کارایی فرایند اکسیداسیون فتوشیمیایی بر پایه پراکسید هیدروژن ( UV/H2O2 )در معدنی سازی 4-کلروفنل از محیط های آبی

 Introduction and purpose: Chlorophenol is known as one of the toxic and dangerous pollutants in industrial wastewaters that’s a essential to it’s removal from industrial wastewaters and ground waters. The aim of this study was to investigate the efficiency of 4-Chlorophenol (4-CP) degradation using Ultraviolet/Hydrogen Peroxide process (UV/H2O2). Methods: The variables of the present study inc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012