Evaluation of a new air displacement plethysmograph for measuring human body composition.

نویسندگان

  • M A McCrory
  • T D Gomez
  • E M Bernauer
  • P A Molé
چکیده

A new air displacement plethysmograph, the BOD POD (BP), was evaluated in comparison to hydrostatic weighing (HW). Sixty-eight adult subjects (26 F, 42 M) varying widely in age (range 20-56 yr), ethnicity, and fatness participated in this study. Same-day test-retest reliability was assessed in a subsample of 16 subjects (9 F, 7 M) and validity was assessed in all subjects (N = 68). The test-retest coefficients of variation (CV) for %FAT measured by BP (%FATBP) and HW (%FATHW) were not significantly different (1.7% +/- 1.1% and 2.3% +/- 1.9% for BP and HW, respectively (mean +/- SD)), indicating excellent reliability for both methods. Validity of percent fat measured by the BP (%FATBP) was also excellent. The mean difference in %FAT (BP - HW) was -0.3 +/- 0.2 (SEM), with a 95% confidence interval of -0.6 to 0 %FAT. The regression equation (%FATHW = 1.86 + 0.94 %FATBP; r2 = 0.93, SEE = 1.81) was not significantly different from the line of identity (%FATHW = %FATBP), and did not differ by gender. These findings indicate that the BOD POD is a highly reliable and valid method for determining %FAT in adult humans in comparison to HW. This new method has several advantages over HW in that it is quick, relatively simple to operate and may be able to accommodate special populations such as the obese, elderly, and disabled.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a new pediatric air-displacement plethysmograph for body-composition assessment by means of chemical analysis of bovine tissue phantoms1–3

Background: Body-composition assessment reflects infant growth and nutritional status but is limited by practical considerations, accuracy, and safety. Objective: This study evaluated the precision and accuracy of a new air-displacement plethysmography (ADP) system for pediatric body-composition assessment. Design: We used 24 phantoms constructed from bovine lean muscle and fat. The phantoms va...

متن کامل

Body composition by air-displacement plethysmography by using predicted and measured thoracic gas volumes.

The BOD POD, a new air-displacement plethysmograph for measuring human body composition, utilizes the inverse relationship between pressure and volume (Boyle's law) to measure body volume directly. The quantity of air in the lungs during tidal breathing, the average thoracic gas volume (Vtg), is also measured by the BOD POD by using a standard plethysmographic technique. Alternatively, the BOD ...

متن کامل

A Comparison of Procedures for Increasing Blood Flow to Limbs Using an Improved Optical Plethysmograph

Measuring the minute volume of blood flow through an extremity at rest, or in response to a physiological stimulus, offers a useful means of evaluating the status of its vascular bed. Hewlett and Van Zwaluwenburg (1) used for this purpose a plethysmograph based upon the principle demonstrated by Brodie (2) wherein sudden occlusion of the veins draining the limb produces an increase in limb size...

متن کامل

A Comparison of Procedures for Increasing Blood Flow to Limbs Using an Improved Optical Plethysmograph.

Measuring the minute volume of blood flow through an extremity at rest, or in response to a physiological stimulus, offers a useful means of evaluating the status of its vascular bed. Hewlett and Van Zwaluwenburg (1) used for this purpose a plethysmograph based upon the principle demonstrated by Brodie (2) wherein sudden occlusion of the veins draining the limb produces an increase in limb size...

متن کامل

Evaluation of body composition: why and how?1,2

Evaluation of human body composition in vivo remains a critical component in the assessment of nutritional status of an individual. Whereas traditional measurements of standing height and body weight provide information on body mass index and, hence, the risk of some chronic diseases, advanced technologies, such as dual X-ray absorptiometry, air displacement plethysmography and various forms of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medicine and science in sports and exercise

دوره 27 12  شماره 

صفحات  -

تاریخ انتشار 1995