Quantitative LVEF and qualitative regional function from gated thallium-201 perfusion SPECT.

نویسندگان

  • G Germano
  • J Erel
  • H Kiat
  • P B Kavanagh
  • D S Berman
چکیده

UNLABELLED This study investigates the feasibility of routine clinical 201Tl gated perfusion SPECT (gated Tl), and compares quantitative left ventricular ejection fraction (LVEF) and visually-assessed regional wall motion and thickening to analogous values obtained from 99mTc-sestamibi gated perfusion SPECT (gated MIBI). METHODS We studied 121 patients with a rest gated Tl (3-3.5 mCi, 35 sec/ projection/poststress gated MIBI (25-30 mCi, 25 sec/projection) separate dual-isotope protocol on a 90 degrees dual-detector camera. Automatic quantitation of LVEFs was accomplished using previously developed and validated software, while visual scoring of motion and thickening was performed using four-point scales. RESULTS Average myocardial counts were lower in gated Tl images (306 +/- 81 counts/pixel) compared to gated MIBI images (789 +/- 237 counts/pixel). The quality of gated Tl images was ranked as excellent, good, fair and poor in 24.0%, 42.1%, 24.8% and 9.1%, respectively, of the patients, compared to 43.0%, 43.8%, 9.1% and 4.1%, respectively, for gated MIBI images. Quantitative-gated Tl and gated MIBI LVEFs correlated well (y = 0.11 + 1.05x, r = 0.918, SEE = 6.35). Possible poststress myocardial stunning may have caused gated Tl LVEFs to overestimate gated MIBI LVEFs by a larger (p = 0.03) amount in ischemic patients (n = 47, y = -0.69 + 1.09x, r = 0.914, s.e.e. = 6.44) compared to nonischemic patients (n = 64, y = -1.58 + 1.05x, r = 0.919, s.e.e. = 5.93), the residual difference in LVEFs for this latter group being likely due to different isotope resolution in conjunction with small left ventricles. Exact agreement between gated Tl and gated MIBI segmental myocardial function in 41 nonischemic patients was 92.2% (kappa = 0.619) and 95.4% (kappa = 0.586) for motion and thickening scores, respectively. CONCLUSION Thallium-201 gated SPECT imaging can be effectively performed on the majority of patients in our clinical environment and offers the opportunity to assess both myocardial perfusion and function using one injection and one imaging sequence, similarly to what is done with 99mTc-based agents.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prognostic value of ECG-gated thallium-201 single-photon emission tomography in patients with coronary artery disease.

BACKGROUND The phenomenon of reversible impairment in LV function has been well described and is known as myocardial stunning. OBJECTIVE Thallium-201 myocardial perfusion gated SPECT was used to evaluate myocardial stunning and its incremental prognostic value in patients with coronary artery disease. PATIENTS AND METHODS Fifty-six patients (aged 63+/-11 years) with coronary artery disease ...

متن کامل

Repeatability and Reproducibility of Thallium-201 Gated SPECT for the Measurement of Left Ventricular Function

Received 10/11/2004; revised 11/8/2004; accepted 11/12/2004. For correspondence or reprints contact: Guang-Uei Hung, M.D., Department of Nuclear Medicine, Changhua Christian Hospital, 135 Nan-Shiao Street, Changhua 500, Taiwan. Tel: (886)4-7238595 ext. 3091, Fax: (886)4-7232942, E-mail: [email protected] Background: Gated myocardial perfusion single photon emission computed tomography (SPECT) h...

متن کامل

Dipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings

  Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...

متن کامل

Normal values of left ventricular functional indices in gated 99mTc-MIBI myocardial perfusion SPECT

  Introduction: Although left ventricular(LV) function parameters measured by gated myocardial perfusion SPECT (GSPECT) have been validated, experimental data have revealed that the calculated the LV function parameters using GSPECT are affected by patient populations as well as particular acquisition and processing conditions. We tried to determine the normal values ...

متن کامل

Prognostic Value of Functional Variables as Assessed by Gated Thallium-201 Myocardial Perfusion Single Photon Emission Computed Tomography for Major Adverse Cardiac Events in Patients with Coronary Artery Disease.

PURPOSE Gated single photon emission computed tomography (SPECT) using thallium-201 (Tl-201) has the capacity to evaluate the earlier post-stress (PS) function compared to technetium-99m labeled tracers, and may be more sensitive in detecting transient ventricular dysfunction caused by stress-induced ischemia. The purpose of this study was to assess the prognostic value of functional variables ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 38 5  شماره 

صفحات  -

تاریخ انتشار 1997