A New Highly Sensitive Method to Assess Respiration Rates and Kinetics of Natural Planktonic Communities by Use of the Switchable Trace Oxygen Sensor and Reduced Oxygen Concentrations
نویسندگان
چکیده
Oxygen respiration rates in pelagic environments are often difficult to quantify as the resolutions of our methods for O2 concentration determination are marginal for observing significant decreases during bottle incubations of less than 24 hours. Here we present the assessment of a new highly sensitive method, that combine Switchable Trace Oxygen (STOX) sensors and all-glass bottle incubations, where the O2 concentration was artificially lowered. The detection limit of respiration rate by this method is inversely proportional to the O2 concentration, down to <2 nmol L(-1) h(-1) for water with an initial O2 concentration of 500 nmol L(-1). The method was tested in Danish coastal waters and in oceanic hypoxic waters. It proved to give precise measurements also with low oxygen consumption rates (∼7 nmol L(-1) h(-1)), and to significantly decrease the time required for incubations (≤14 hours) compared to traditional methods. This method provides continuous real time measurements, allowing for a number of diverse possibilities, such as modeling the rate of oxygen decrease to obtain kinetic parameters. Our data revealed apparent half-saturation concentrations (Km values) one order of magnitude lower than previously reported for marine bacteria, varying between 66 and 234 nmol L(-1) O2. Km values vary between different microbial planktonic communities, but our data show that it is possible to measure reliable respiration rates at concentrations ∼0.5-1 µmol L(-1) O2 that are comparable to the ones measured at full air saturation.
منابع مشابه
New and fast method to quantify respiration rates of bacterial and plankton communities in freshwater ecosystems by using optical oxygen sensor spots.
A new method of respiration rate measurement based on oxygen luminescence quenching in sensor spots was evaluated for the first time for aquatic bacterial communities. The commonly used Winkler and Clark electrode methods to quantify oxygen concentration both require long incubation times, and the latter additionally causes signal drift due to oxygen consumption at the cathode. The sensor spots...
متن کاملI-11: The Use of Oxygen Consumption for Oocyte and Embryo Selection
Assisted human reproduction is characterized by a high variability in results regarding pregnancy and birth rates. In fact, in a cohort of fertilized oocytes from the same stimulation cycle, the development rate varies drastically, even though produced at the same time and under similar conditions. This variability results in large differences in implantation potential of human embryos develope...
متن کاملPlanktonic-based assessment of the landside-dammed lake (Erzurum-Turkey)
The aim of this study was to identify the variation of plankton communities in the Tortum Lake. Changes in phytoplankton and zooplankton communities in relation to the abiotic environment were analyzed using multivariate analysis. Water samples were taken monthly from three sampling points of the Tortum Lake between June 2012 and May 2013. Water temperature (5.28-23.05°C), dissolved oxygen ...
متن کاملساخت و بررسی عمل کرد سنسور اکسیژن و بهبود آن با استفاده از نیمه هادی اکسید فلزات تیتانیوم و سزیم و قلع به عنوان مرجعهای جامد
We report the development of different types of oxygen sensors based on yittria-stabilized zirconia (YSZ) as a solid electrolyte. The conventional oxygen sensor is a concentration cell with two porous Pt electrodes, one of which is exposed to air as a constant (reference) oxygen concentration and the other is exposed to automobile exhaust gas of variable oxygen concentration, depending on the a...
متن کاملPlanktonic-based assessment of the landside-dammed lake (Erzurum-Turkey)
The aim of this study was to identify the variation of plankton communities in the Tortum Lake. Changes in phytoplankton and zooplankton communities in relation to the abiotic environment were analyzed using multivariate analysis. Water samples were taken monthly from three sampling points of the Tortum Lake between June 2012 and May 2013. Water temperature (5.28-23.05°C), dissolved oxygen (1.5...
متن کامل