Development of Piv Technique under Magnetic Fields and Measurement of Turbulent Pipe Flow of Flibe Simulant Fluid
نویسندگان
چکیده
An investigation of MHD effects on a Flibe (Li2BeF4) simulant fluid has been conducted under the US-Japan JUPITER-II collaboration program using “FLIHY” pipe flow facility at UCLA. The present paper reports a development of unique experimental techniques using aqueous solution of potassium hydroxide as a Flibe simulant. In order to apply a particle image velocimetry (PIV) technique for magnetic field condition, special optical devices were developed. The PIV measurements of MHD turbulent pipe flow at Re = 5300 were performed, and modification of the mean flow velocity as well as turbulence suppression was observed. A flat velocity profile in the pipe center and a steep velocity gradient in the near-wall region at Ha = 20 exhibits typical characteristics of Hartmann flow.
منابع مشابه
The Experimental Study of Nanoparticles Effect on Thermal Efficiency of Double Pipe Heat Exchangers in Turbulent Flow
In this work, the characteristics of flow and heat transfer of a fluid containing nano particles of aluminum oxide with the water volume fraction (0.1-0.2-0.3)(V/V) percent of the reports. The overall heat transfer coefficient, heat transfer and the average heat transfer fluid containing nano water - aluminum oxide in a horizontal double pipe counter flow heat exchanger under turbulent flow con...
متن کاملVisualization of Complex Flow Structures by Matched Refractive-Index PIV Method
With the development of computers and their surrounding equipments, the simulation of complicated flow structures around aircrafts will further become easier and cheaper by applying computational fluid dynamics. However, in order to judge whether the flow field obtained is reasonable or not, turbulent models and/or numerical schemes should be selected based on the comparison with experimental r...
متن کاملMulti objective optimization of the vibration analysis of composite natural gas pipelines in nonlinear thermal and humidity environment under non-uniform magnetic field
The fluid-conveying pipe is a fundamental dynamical problem in the field of fluid– structure interactions. In recent years considerable attention has been given to the lateral vibrations of pipes containing by a moving fluid. In this paper, the vibration analysis of composite natural gas pipeline in the thermal and humidity environment is studied. The effect of the non-uniform magnetic field is...
متن کاملAn Experimental Study of Turbulent Mixing in a Tee Mixer Using PIV and PLIF
Turbulent scalar mixing in the near field of a tee mixer (transverse jet in a pipe) is studied using Particle Image Velocimetry (PIV) and Planar Laser Induced Fluorescence (PLIF). Two jet-to-pipe velocity ratios, r = 3.06 and r = 5.04, are investigated for a turbulent pipe flow at a Reynolds number of 20,850. The laser measurement techniques are described, typical flow structures in the near fi...
متن کاملThe Wall-PIV Measurement Technique for Near Wall Flow Fields in Biofluid Mechanics
This chapter describes the development of a new time resolved 3D PIV technique for near wall flow field measurements. This measurement technique, called wall-PIV, is based on Beer-Lambert’s law. It substitutes the classical PIV laser sheet by a diffuse, monochromatic full-field illumination that is limited to the near wall region by an absorbing molecular dye in the fluid. Aimed range of applic...