Blood-pool MR contrast material for detection and characterization of focal hepatic lesions: initial clinical experience with ultrasmall superparamagnetic iron oxide (AMI-227).

نویسندگان

  • S Saini
  • R R Edelman
  • P Sharma
  • W Li
  • W Mayo-Smith
  • G J Slater
  • P J Eisenberg
  • P F Hahn
چکیده

OBJECTIVE AMI-227 is an ultrasmall superparamagnetic iron oxide colloid known to enhance tissue T1 and T2 relaxation rates. Animal studies show that AMI-227 has an estimated blood half-life of more than 200 min. In this study, we evaluated the clinical utility of AMI-227 as an MR contrast agent for detection and characterization of focal hepatic lesions, with MR imaging done while the contrast agent is in the intravascular space (blood-pool phase). SUBJECTS AND METHODS Twenty-two patients with known or suspected focal hepatic masses underwent T1- and T2-weighted MR imaging of the liver at 1.5 T before and immediately after drip infusion of AMI-227 at doses of 0.8, 1.1, or 1.7 mg Fe/kg. Unenhanced and contrast-enhanced images were analyzed qualitatively (lesion detection and tissue characterization) and quantitatively (lesion-liver contrast-to-noise ratio). RESULTS AMI-227 enhanced signal in normal liver and blood vessels on T1-weighted images and decreased signal in these tissues on T2-weighted images. Qualitatively and quantitatively, lesion-liver contrast was increased for solid tumors (non-cyst and nonhemangioma) at all three doses (p < .02) on both T1- and T2-weighted images. Differentiation between blood vessels and small lesions was easier on contrast-enhanced images, which allowed increased confidence in excluding lesions. Unique enhancement patterns were noted for hemangiomas, solid tumors, and cysts. CONCLUSION Initial clinical experience suggests that AMI-227 is a useful contrast agent for detection and characterization of focal hepatic lesions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Superparamagnetic Iron Oxide-enhanced Magnetic Resonance Imaging and 5-Phase Computed Tomography in the Detection and Characterisation of Focal Liver Lesions

Objective: To compare superparamagnetic iron oxide-enhanced magnetic resonance imaging with 5-phase computed tomography in the detection and characterisation of focal liver lesions. Patients and Methods: We prospectively performed 5-phase computed tomography scans followed by magnetic resonance imaging of the liver with superparamagnetic iron oxide magnetic resonance contrast medium in patients...

متن کامل

Applications of ultrasmall superparamagnetic iron oxide contrast agents in the MR study of animal models.

Ultrasmall superparamagnetic iron oxide nanoparticles have been widely used during the past decade as MR intravascular contrast agents in the study of animal models. Such agents enhance both T1 and T2/T2* relaxation, although for animal studies it is the later type of enhancement that is most commonly exploited. Their strong microscopic intravascular susceptibility effect enables the local bloo...

متن کامل

Contrast-enhanced MR imaging of atherosclerosis using citrate-coated superparamagnetic iron oxide nanoparticles: calcifying microvesicles as imaging target for plaque characterization

OBJECTIVE To evaluate the suitability of citrate-coated very small superparamagnetic iron oxide particles (VSOP) as a contrast agent for identifying inflammation in atherosclerotic lesions using magnetic resonance imaging (MRI). METHODS AND RESULTS VSOP, which have already been evaluated as a blood pool contrast agent for MR angiography in human clinical trials, were investigated in Watanabe ...

متن کامل

Ultrasmall cationic superparamagnetic iron oxide nanoparticles as nontoxic and efficient MRI contrast agent and magnetic-targeting tool

Fully dispersible, cationic ultrasmall (7 nm diameter) superparamagnetic iron oxide nanoparticles, exhibiting high relaxivity (178 mM(-1)s(-1) in 0.47 T) and no acute or subchronic toxicity in Wistar rats, were studied and their suitability as contrast agents for magnetic resonance imaging and material for development of new diagnostic and treatment tools demonstrated. After intravenous injecti...

متن کامل

Comparison of ultrasmall particles of iron oxide (USPIO)-enhanced T2-weighted, conventional T2-weighted, and gadolinium-enhanced T1-weighted MR images in rats with experimental autoimmune encephalomyelitis.

BACKGROUND AND PURPOSE Ultrasmall particles of iron oxide (USPIO) constitute a contrast agent that accumulates in cells from the mononuclear phagocytic system. In the CNS they may accumulate in phagocytic cells such as macrophages. The goal of this study was to compare USPIO-enhanced MR images with conventional T2-weighted images and gadolinium-enhanced T1-weighted images in a model of experime...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJR. American journal of roentgenology

دوره 164 5  شماره 

صفحات  -

تاریخ انتشار 1995