In-line Acoustic System to Position and Monitor Infant-sized Endotracheal Tubes
نویسندگان
چکیده
Ensuring that the distal end of an endotracheal tube is properly located within the trachea, and that the tube is not obstructed by mucous deposition, is a major clinical concern. This concern is heightened in infant care, where the relatively small geometries predicate higher risks. A novel acoustic system was developed to allow for the continuous monitoring of endotracheal tube position and patency. A miniature sound source and two sensing microphones are placed in-line between the ventilator hose and the proximal end of the endotracheal tube. Reflections of an acoustic pulse from the endotracheal tube lumen and the airways are digitally analyzed to estimate the location and degree of obstruction, as well as the position of the distal end of the tube in the airway. The system was evaluated in a rabbit model. During advancement and retraction of the distal end of the tube within the trachea, changes in position were estimated acoustically to within -0.4 f 2.0 mm (mean f 95% CI). Through reflection analysis, the system reliably differentiated tracheal from improper bronchial or esophageal placement in all cases. In addition, the system acoustically estimated the area of intralumenal obstruction to within 5.4 f 8.6 YO.
منابع مشابه
Optimal Line and Tube Placement in Very Preterm Neonates: An Audit of Practice
BACKGROUND Placement of endotracheal tubes (ETTs) and umbilical catheters (UCs) is essential in very preterm infant care. The aim of this study was to assess the effect of an educational initiative to optimize correct placement of ETTs and UCs in very preterm infants. METHODS A pre-post study design, evaluating optimal radiological position of ETTs and UCs in the first 72 h of life in infants...
متن کاملHead position and oral vs nasal route as factors determining endotracheal tube resistance.
STUDY OBJECTIVE We performed this in vitro study to determine the following: (1) if there is any significant difference in resistance between comparably sized endotracheal tubes (ETTs) in simulated anatomic oral and nasal conformations: (2) if neck flexion would increase the resistance of the ETT; and (3) if a wire-reinforced tube in simulated oral conformation would minimize the resistance inc...
متن کاملSafe Use of Flammable Endotracheal Tubes During Anesthesia for Laryngeal Laser Surgery-Report of 1024 Cases and a Brief Literature Review
Introduction: One of the major concerns in laryngeal laser surgery is the risk of airway fire. The introduction ofwrapped tubes and metal tubes has reduced the fire hazards. However, these tubes are expensive and do not provide convenient access to the surgical field. There are few laboratory studies addressing the resistance of polyvinylchloride tubes against ignition in the given circum...
متن کاملPreliminary Characterization Tests of Detectors of on-Line Monitor Systems of the Italian National Center of Oncological Hadron-Therapy (CNAO)
Introduction Hadron-therapy is an effective technique used to treat tumors that are located between or nearby vital organs. The Italian National Center of Oncological Hadron-therapy (CNAO) has been realized as the first facility in Italy to treat very difficult tumors with protons and Carbon ions. The on-line monitor system for CNAO has been developed by the Department of Physics of the Univers...
متن کاملPlain endotracheal tube insertion carries greater risk for malpositioning than does reinforced endotracheal tube insertion in females
provided the original work is properly cited. CC Malpositioning of an endotracheal tube within the airway can lead to serious complications, such as endobronchial intubation, which may cause collapse of the nonventilated lung and barotrauma of the ventilated lung or vocal cord paralysis and accidental extubation [1]. We retrospectively identified 204 (54 plain tubes and 54 reinforced tubes in m...
متن کامل