Photothermal Signal Distribution Analysis (PhoSDA): Supplement

نویسندگان

  • Markus Selmke
  • Marco Braun
  • Romy Schachoff
  • Frank Cichos
چکیده

The amplitude Φ0, which has the units of an inverse length unit, quantifies the rel. PT signal of the particle. Thus, for small particles it scales with the volume, i.e. Φ0 ∝ R3. The maximum signal Φmax is obtained at z+ = [z0 − δpp] /2 while the minimum signal Φmin is obtained at z− = [z0 + δpp] /2 with the positive axial peak-to-peak distance δpp of the detection volume eqn (1) given as δ2 pp = z2 0 + γ 2ω2 ρ. The maximum signal is Φmax = Φ (z+) while the minimum signal is Φmin = Φ (z−). Equation 1 may be inverted to yield the radius ρ as a function of z for a given signal value Φ:

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of the probe beam size on the photothermal reflectance signal

The influence of the probe beam size and shape on the photothermal reflectance signal is discussed. An analytical formula for the case of Gaussian power distribution is derived. The potentials of the photothermal microscope for local investigation of thermal parameters of solids and solid structures are outlined using computer simulation.

متن کامل

تابع توزیع سه بعدی دمای لیزر القاییده در طیف نمایی جابجایی گرما نوری

  In this paper we present a detailed theoretical treatment of the 3-D temperature distribution induced by laser beam in photothermal displacement spectroscopy. We assume that a solid sample, which is deposited on a substrate and is in contact with a fluid, is irradiated by an intensity modulated cw laser source. By using a technique based on Greens function and integral transformations we find...

متن کامل

Label-free imaging of heme proteins with two-photon excited photothermal lens microscopy

Heme proteins, such as hemoglobins and cytochromes, play important roles in various biological processes. Here we employ the two-photon excited photothermal effect as a contrast mechanism to map heme proteins distribution. Particularly, both a thermal lens scheme and a high-frequency modulation are utilized to enhance the signal-to-noise ratio. We demonstrate label-free imaging of individual re...

متن کامل

Fast 3D visualization of endogenous brain signals with high-sensitivity laser scanning photothermal microscopy

A fast, high-sensitivity photothermal microscope was developed by implementing a spatially segmented balanced detection scheme into a laser scanning microscope. We confirmed a 4.9 times improvement in signal-to-noise ratio in the spatially segmented balanced detection compared with that of conventional detection. The system demonstrated simultaneous bi-modal photothermal and confocal fluorescen...

متن کامل

Non-linearity in photothermal radiometric imaging

Non-linear effects occurring in photothermal microscopes based on principle of photothermal radiometry are studied as a hnction of the laser power and of the modulation frequency. For stainless steel, a second harmonic component of up to 11 % of the hndamental amplitude is found. Phase shifts of up to 20 degrees are observed as a hnction of the modulation frequency. The nonlinearity is mainly d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013