Stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture: a comparative finite element study
نویسندگان
چکیده
PURPOSE The purpose of this study is to compare the stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture. METHODS A three-dimensional (3D) finite element model of the medial tibial plateau fracture (Schatzker type IV fracture) was created. An axial force of 2500 N with a distribution of 60% to the medial compartment was applied to simulate the axial compressive load on an adult knee during single-limb stance. The equivalent von Mises stress, displacement of the model relative to the distal tibia, and displacement of the implants were used as the output measures. RESULTS The mean stress value of the plate-screw fixation system was 18.78 MPa, which was significantly (P < 0.001) smaller than that of the screw fixation system. The maximal value of displacement (sum) in the plate-screw fixation system was 2.46 mm, which was lower than that in the screw fixation system (3.91 mm). The peak stress value of the triangular fragment in the plate-screw fixation system model was 42.04 MPa, which was higher than that in the screw fixation model (24.18 MPa). But the mean stress of the triangular fractured fragment in the screw fixation model was significantly higher in terms of equivalent von Mises stress (EVMS), x-axis, and z-axis (P < 0.001). CONCLUSIONS This study demonstrated that the load transmission mechanism between plate-screw fixation system and screw fixation system was different and the stability provided by the plate-screw fixation system was superior to the screw fixation system.
منابع مشابه
Comparison of theoretical fixation stability of three devices employed in medial opening wedge high tibial osteotomy: a finite element analysis
BACKGROUND Medial open wedge high tibial osteotomy is a well-established procedure for the treatment of unicompartmental osteoarthritis and symptomatic varus malalignment. We hypothesized that different fixation devices generate different fixation stability profiles for the various wedge sizes in a finite element (FE) analysis. METHODS Four types of fixation were compared: 1) first and 2) sec...
متن کاملNewly designed anterolateral and posterolateral locking anatomic plates for lateral tibial plateau fractures: a finite element study
BACKGROUND Lateral column tibial plateau fracture fixation with a locking screw plate has higher mechanical stability than other fixation methods. The objectives of the present study were to introduce two newly designed locking anatomic plates for lateral tibial plateau fracture and to demonstrate their characteristics of the fixation complexes under the axial loads. METHODS Three different 3...
متن کاملThe sustentaculum tali screw fixation for the treatment of Sanders type II calcaneal fracture: A finite element analysis
OBJECTIVE In the surgery of calcaneal fracture, whether the sustentaculum tali screw should always be placed is widely controversial. The aim of this study was to explore the necessity and function of the sustentaculum tali screw placement for the treatment of Sanders type II calcaneal fracture. METHODS The finite element analysis was used in this study. After the establishment of the finite ...
متن کاملClosed reduction and percutaneous screw fixation for tibial plateau fractures.
PURPOSE To evaluate treatment outcomes of closed reduction and percutaneous screw fixation for tibial plateau fractures. METHODS 48 men and 8 women aged 19 to 61 (mean, 36) years underwent closed reduction and percutaneous screw fixation for closed tibial plateau fractures with <5 mm depression. According to the Schatzker classification, patients were classified into type I (n=9), type II (n=...
متن کاملThe effect of screw thread length on initial stability of Schatzker type 1 tibial plateau fracture fixation: a biomechanical study
BACKGROUND This study compares the cyclic loading properties and failure loads of two screw combinations on a synthetic Schatzker type 1 tibia fracture model. Our hypothesis was that after adequate compression with first a partially threaded screw, addition of a fully threaded screw would provide more stability than an addition of a second partially threaded screw. METHODS The Schatzker type ...
متن کامل