Influence of Resolution on Scanner Noise Perceptibility
نویسندگان
چکیده
The perceptibility of scanner noise as a function of resolution is studied using a model for the human visual system and for the scanner noise. The visual system is modeled using a point-wise nonlinearity followed by a lightness contrast-sensitivity-function. The noise model incorporates a signal-dependent noise component and a signal-independent noise component. The system is analyzed to determine the perceived signal-to-noise ratio (SNR) as a function of the measured SNR. The findings support the intuition that as resolution is increased a lower measured SNR is acceptable because the eye effectively averages over the pixels at the higher resolution. Roughly speaking, the acceptable levels of measured SNR are inversely proportional to the resolution of the scanner. The overall impact of increasing resolution in a scanner by changing the sensor while keeping the lamp and the optics fixed is also analyzed in the same framework. The analysis indicates that if the signal-dependent component of the noise dominates, the perceived SNR does not degrade with increased resolution, but if signal-independent noise is also significant, the perceived SNR degrades with an increase in
منابع مشابه
The perceptibility curve test applied to CCD and two methods of digitization of dental film-based radiographs
Objectives: Several methods of image acquisition are accessible in dentistry. There is no overall acceptable method for image digitization so all different types of images can be comparable. The objective of this study was to compare the diagnostic accuracy of different methods of image digitization. Methods: This accuracy diagnostic test study used perceptibility curve test which first intr...
متن کاملThe effect of focal spot size on the spatial resolution of variable resolution X-ray CT scanner
Background: A variable resolution X-ray (VRX) CT scanner provides a great increase in the spatial resolution. In VRX CT scanners, the spatial resolution of the system and its field of view (FOV) can be changed according to the object size. One of the main factors that limit the spatial resolution of VRX CT scanner is the effect of the X-ray focal spot. Materials and Methods: A theoreti...
متن کاملبررسی تاثیر کرنل های مختلف بازسازی تصویر بر روی نویز و رزولوشن فضایی تصاویر سی تی اسکن: مطالعه بر روی فانتوم
Introduction: Noise and spatial resolution (SR) are the main characteristics of image quality in CT scanning affected by different radiation and technical parameters. One of the important parameters are reconstruction kernels. Different reconstruction kernels are used for noise reduction and/or edge-enhancement purposes. In this study, we investigate some reconstruction kern...
متن کاملValidation and evaluation of a GATE model for MAMMI PET scanner
Introduction:MAMMI is a dedicated PET based on high resolution detectors placed close to the breast. In this study, we presented a GATE model for the simulation of MAMMI scanner and model its performance of the MAMMI based on an adaptation of the NU 4-2008 NEMA standard. Methods:A detailed of geometry MAMMI system that uses scintillation crystals coupled...
متن کاملOptimization of Imaging Parameters in Micro-CT Scanner Based On Signal-To-Noise Ratio for the Analysis of Urinary Stone Composition
Introduction: Micro-CT scanner with a resolution of about 5 micrometers is one of the modalities used to create three-dimensional/two-dimensional images of urinary stones. This study aimed to optimize imaging parameters in micro-computed tomography (CT) scanner based on the signal-to-noise ratio (SNR) of urinary stones for the analysis of stone composition. <stro...
متن کامل