Tungsten trioxide ( WO , ) as an actuator electrode material for ISFET - based coulometric sensor - actuator systems
نویسندگان
چکیده
Acid or base concentrations can be determined by performing an acid-base titration with OHor H+ ions, coulometricaliy generated by the electrolysis of water at a noble metal actuator electrode. This can be done very rapidly if the actuator electrode is in close proximity to an ISFET which is used as the indicator electrode to detect the equivalence point in the titration curve. In order to restrict the effect of interfering redox reactions at the actuator electrode during coulometric generation, eiectroactive actuator materials have been studied which can exchange H+ ions at a lower electrode potential than the potential of anodic water electrolysis. In this paper, electrochemically grown tungsten trioxide (WOJ is proposed as an actuator electrode material. At a WOa electrode, H+ ions can be generated by a redox reaction at approximately 0.1 V versus SCE in a mildly alkaline solution (OS-7 mM KOH) (anodic water electrolysis at a Pt electrode occurs at 1.5 V versus SCE). The observed thermodynamic and kinetic behaviour of the redox reaction is in good agreement with the theoretical predictions. Disadvantages of WO, are its slow dissolution in aqueous solutions and the restriction that a titration at a W03 electrode can only be performed in alkaline solutions.
منابع مشابه
Dynamic Behaviour of ISFET - based Sensor - Actuator Systems
Rapid acid-base titrations can be performed at the surface of a noble-metal electrode with coulometrically generated ions. An ISFET is used as an indicator electrode to detect the equivalence point in the resulting titration curve. The time needed to reach the equivalence point is typically 0.5 to 10 s for acid/base concentrations ranging from 0.5 x lop3 to 20 x lop3 mol 1 -I. A model is presen...
متن کاملPreparation of Iridium Oxide and its Application in Sensor-Actuator Systems
Acid or base concentrations can be determined by coulometric titration. A new alliridium oxide sensor-actuator device is presented, of which the titrant is generated by a reversible redox reaction occurring in the electroactive iridium oxide actuator electrode, and the equivalence point in the titration curve is detected by the pH-sensitive iridium oxide sensor. The advantage with respect to th...
متن کاملModelling of non-steady-state concentration profiles at ISFET-based coulometric sensor-actuator systems
Acid or base concentrations can be determmed very rapidly by performmg an acid-base titration with coulometncally generated OHor H+ ions at a noble metal actuator electrode m close proximity to the pH-sensitive gate of an ion-sensitive field effect transistor (ISFET) The ISFET is used as the mdicator electrode to detect the eqmvalence point in the titration curve Typical values for the time nee...
متن کاملA Dipstick Sensor for Coulometric Acid-base Titrations
By performing an acid-base titration by coulometric generation of OHor H+ ions at an inert electrode in close proximity to the pH-sensitive gate of an ISFET, it is possible to determine the acid or base concentration of a solution using the ISFET as an indicator device for the equivalence point in the titration curve. Typical values for the titration time are 0.1 to 10 s for acid or base concen...
متن کاملSimplified design of the coulometric sensor -actuator system by <he application of a time-dependent actuator current
Acid or base concentrations can be determined by performing an acid-base titration with coulometrically generated OHor H+ ions at a noble metal actuator electrode in close proximity to the pH-sensitive gate of an ISFET. It is shown, both theoretically and experimentally, that the relation between the acid or base concentration and the time needed to reach the equivalence point in the resulting ...