Optimized radiofrequency coil setup for MR examination of living isolated rat hearts in a horizontal 9.4T magnet.

نویسندگان

  • Maelene Lohezic
  • Christian Bollensdorff
  • Matthias Korn
  • Titus Lanz
  • Vicente Grau
  • Peter Kohl
  • Jürgen E Schneider
چکیده

PURPOSE (i) To optimize an MR-compatible organ perfusion setup for the nondestructive investigation of isolated rat hearts by placing the radiofrequency (RF) coil inside the perfusion chamber; (ii) to characterize the benefit of this system for diffusion tensor imaging and proton ((1) H-) MR spectroscopy. METHODS Coil quality assessment was conducted both on the bench, and in the magnet. The benefit of the new RF-coil was quantified by measuring signal-to-noise ratio (SNR), accuracy, and precision of diffusion tensor imaging/error in metabolite amplitude estimation, and compared to an RF-coil placed externally to the perfusion chamber. RESULTS The new design provided a 59% gain in signal-to-noise ratio on a fixed rat heart compared to using an external resonator, which found reflection in an improvement of living heart data quality, compared to previous external resonator studies. This resulted in 14-29% improvement in accuracy and precision of diffusion tensor imaging. The Cramer-Rao lower bounds for metabolite amplitude estimations were up to 5-fold smaller. CONCLUSION Optimization of MR-compatible perfusion equipment advances the study of rat hearts with improved signal-to-noise ratio performance, and thus improved accuracy/precision.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A High-Throughput Eight-Channel Probe Head for Murine MRI at 9.4 T

Murine MRI studies are conducted on dedicated MR systems, typically equipped with ultra-high-field magnets (>or=4.7 T; bore size: approximately 12-25 cm), using a single transmit-receive coil (volume or surface coil in linear or quadrature mode) or a transmit-receive coil combination. Here, we report on the design and characterization of an eight-channel volume receive-coil array for murine MRI...

متن کامل

A mobile high-field magnetic resonance system for neurosurgery.

OBJECT The authors' goal was to place a mobile, 1.5-tesla magnetic resonance (MR) imaging system into a neurosurgical operating room without adversely affecting established neurosurgical management. The system would help to plan accurate surgical corridors, confirm the accomplishment of operative objectives, and detect acute complications such as hemorrhage or ischemia. METHODS The authors us...

متن کامل

Phased Array Imaging in Mouse Hearts using an 8-Channel Phased Array Coil at 9.4 Tesla

Introduction: Cardiac magnetic resonance imaging (CMR) in surgically or genetically modified mice is typically performed using single dedicated volume or surface coils. The development of coil arrays to speed-up CMR becomes more challenging with increasing magnetic field strength and reduced bore size of the magnet. While the use of coil arrays for cardiac MR exams of the human heart is well es...

متن کامل

In vivo(39)K, (23)Na and (1)H MR imaging using a triple resonant RF coil setup.

The maintenance of a gradient of potassium and sodium ions across the cell membranes is essential for the physiological function of the mammal organism. The measurement of the spatial distribution of pathologically changing ion concentrations of (23)Na and (39)K with magnetic resonance imaging offers a promising approach in clinical diagnostics to measure tissue viability. Existing studies were...

متن کامل

Interrogation of living myocardium in multiple static deformation states with diffusion tensor and diffusion spectrum imaging

Diffusion tensor magnetic resonance imaging (MRI) reveals valuable insights into tissue histo-anatomy and microstructure, and has steadily gained traction in the cardiac community. Its wider use in small animal cardiac imaging in vivo has been constrained by its extreme sensitivity to motion, exaggerated by the high heart rates usually seen in rodents. Imaging of the isolated heart eliminates r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 73 6  شماره 

صفحات  -

تاریخ انتشار 2015