Applying the least squares method for the titrimetric determination of the concentration of VFA.
نویسندگان
چکیده
The titrimetric method is used for on-site measurement of the concentration of volatile fatty acids (VFAs) in anaerobic treatment. In current practice, specific and interpolated pH-volume data points are used to obtain the concentration of VFA by solving simultaneous equations iteratively to convergence (denoted as SEq). Here, the least squares method (LSM) is introduced as an elegant alternative. Known concentrations of VFA (acetic acid and/or propionic acid) ranging from to 200 to 1,000 mg/L were determined using SEq and LSM. Using standard numbers of data points, SEq gave more accurate results compared with LSM. However, results favoured LSM when all data points in the range were included without any interpolation. For model refinement, unit monovalent activity coefficient (f(m) = 1) was found reasonable and arithmetic averages of dissociation constants and molecular weight of 80 mol% acetic acid were recommended in the model for VFA determination of mixtures. An accurate result was obtained with a mixture containing more VFA (butyric acid and valeric acid). In a typical VFA measurement of real anaerobic effluent, a satisfactory result with an error of 14% was achieved. LSM appears to be a promising mathematical model solver for determination of concentration of VFA in the titrimetric method. Validation of LSM in the presence of other electrolytes deserves further exploration.
منابع مشابه
Simultaneous Spectrophotometric Determination of Iron, Cobalt and Copper by Partial Least-Squares Calibration Method in Micellar Medium
Iron, cobalt and copper are metals, which appear together in many real samples, both natural and artificial. Recently a classical univariate micellar colorimetric method has been developed for determination of these metal ions. The organized molecular assemblies such as micelles are used in spectroscopic measurements due to their possible effects on the systems of interest. The ability of mi...
متن کاملSimultaneous Spectrophotometric Determination of Iron, Cobalt and Copper by Partial Least-Squares Calibration Method in Micellar Medium
Iron, cobalt and copper are metals, which appear together in many real samples, both natural and artificial. Recently a classical univariate micellar colorimetric method has been developed for determination of these metal ions. The organized molecular assemblies such as micelles are used in spectroscopic measurements due to their possible effects on the systems of interest. The ability of mi...
متن کاملTitrimetric and Spectrophotometric Methods for the Determination of β-blockers in Pharmaceutical Dosage Form
Three new methods using titrimetric and spectrophotometry are described for the determination of Propranolol Hydrochloride (PPH) and Atenolol (AN) with potassium bromate as the oxidimetric reagent and acid dyes, Methyl orange and Indigo carmine. In direct titrimetric (method A), the drug is titrated directly with bromate in acid medium and in the presence of excess of bromide using methyl orang...
متن کاملSimplex design method in simultaneous spectrophotometric determination of silicate and phosphate in boiler water of power plant and sewage sample by partial least squares
Partial least squares modeling as a powerful multivariate statistical tool was applied tothe simultaneous spectrophotometric determination of silicate and phosphate in aqueoussolutions. The concentration range for silicate and phosphate were 0.02-0.6 and 0.4-3 μg ml-1,respectively. The experimental calibration set was composed with 30 sample solutions using amixture design for two component mix...
متن کاملSpectrophotometric simultaneous determination of nickel, cobalt and copper by orthogonal signal correction–partial least squares
A method for the simultaneous spectrophotometric determination of nickel, cobalt and copper based on theformation of their complexes with 2-(2-Thiazolylazo)-p-Cresol (TAC) in micellar media of Triton X-100 isproposed. The absorbance spectra were recorded in the range of 500 to 800 nm. The linear concentrationrange for nickel, cobalt and copper in solution calibration sets were 0.05–1.80, 0.10–6...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Water science and technology : a journal of the International Association on Water Pollution Research
دوره 66 3 شماره
صفحات -
تاریخ انتشار 2012