Correlation of cerebrovascular symptoms and microembolic signals with the stratified gray-scale median analysis and color mapping of the carotid plaque.

نویسندگان

  • Roman Sztajzel
  • Isabelle Momjian-Mayor
  • Mario Comelli
  • Shahan Momjian
چکیده

BACKGROUND AND PURPOSE To determine whether a stratified gray-scale median (GSM) analysis of the carotid plaque combined with color mapping correlated better with the presence of neurological symptoms and microembolic signals (MES) than a whole plaque measurement. METHODS A total of 131 patients presenting 167 carotid stenoses between 30% and 99% were analyzed by ultrasound. Emboli detection was performed by transcranial Doppler. For each plaque, the GSM values at depth 0 mm (surface) and at one third (30) and one half (50) of the plaque thickness were compared with the values obtained for the whole plaque. The plaque pixels were mapped into 3 colors: red, yellow and green, depending on their GSM value. RESULTS Mean GSM values were lower among symptomatic plaques, but a statistically significant difference between values of the whole plaque and those of the surface was obtained only for MES+ stenoses (P<0.01). In a proportional odds logistic regression model based on 4 subgroups with an increasing clinical risk (MES-/symptoms-; MES-/symptoms+; MES+/symptoms-; +; MES+/symptoms+), low mean GSM values and the predominant red color at the surface were independent factors associated with the presence of symptoms or MES (P<0.0005). Furthermore, compared with a whole plaque measurement, analysis of the surface values predicted systematically with a greater sensitivity and specificity (receiver operating characteristic curves) each one of these 4 subgroups. CONCLUSIONS Low mean GSM values and predominance of the red color at the surface correlated with most of the symptomatic or MES+ stenoses. This combined approach should be further investigated in a longitudinal study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stratified gray-scale median analysis and color mapping of the carotid plaque: correlation with endarterectomy specimen histology of 28 patients.

BACKGROUND AND PURPOSE To determine whether a stratified gray-scale median (GSM) analysis of the carotid plaque combined with color mapping could predict plaque histology better than an overall GSM measurement. METHODS Thirty-one carotid plaques derived from 28 patients undergoing carotid endarterectomy were investigated by ultrasound. GSMs of the whole plaque were used as measurement of echo...

متن کامل

Transcranial Doppler application for risk assessment of stroke in patients with mechanical mitral valve

Introduction: Observing microembolic signals in brain vessels by transcranial Doppler technology is a very common finding in patients with mechanical heart valve. These signals are almost always clinically asymptomatic. The aim of this study was assessment of transcranial Doppler in detecting probability of stroke in patients with mechanical heart valve. Methods: This descriptive study was ca...

متن کامل

18FDG-PET-CT: an imaging biomarker of high-risk carotid plaques. Correlation to symptoms and microembolic signals.

BACKGROUND AND PURPOSE We investigated whether uptake of (18)fluoro-2-deoxy-d-glucose (18FDG) positron emission tomography-computed tomography (PET-CT) correlated to clinical symptoms and presence of microembolic signals (MES) detected by transcranial Doppler in patients with carotid stenosis. METHODS 18FDG-PET-CT and MES detection was performed in consecutive patients with 50% to 99% symptom...

متن کامل

Association between high sensitivity C-reactive protein (hs-CRP) levels and the risk of major adverse cardiovascular events (MACE) and/or microembolic signals after carotid angioplasty and stenting

Background: To evaluate the association between pre/post-procedural high sensitive C-reactive protein (hs-CRP) level and hs-CRP difference, and the risk of major adverse cardiovascular events (MACE) or new diffusion-weighted MRI lesions after carotid angioplasty and stenting (CAS). Methods: In this study, conducted in 2016 in Shiraz (Iran), patients who underwent diagnostic angiography and CAS...

متن کامل

Accuracy of a novel risk index combining degree of stenosis of the carotid artery and plaque surface echogenicity.

BACKGROUND AND PURPOSE The purpose of this study was to determine the accuracy of a risk index in symptomatic or asymptomatic carotid stenoses. METHODS Consecutive patients presenting 50% to 99% carotid stenoses were included. A semiautomated gray scale-based color mapping (red, yellow, and green) of the whole plaque and of its surface was achieved. Surface was defined as the region located b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 2006