High-Speed Railway Traction Power Supply Equipment Condition-Based Maintenance Decision Model Based on Abrasion Analysis
نویسندگان
چکیده
According to abrasion process of machine equipment parts of overhead line system for traction power supply and characters of wear-out failures, considering on factor changes of all kinds of production conditions in practical operation, set permit of abrasion loss in coordinating with normal distribution, and abrasion loss of parts as random variables, and then establish the relation between maintenance costs and random variable of abrasion loss with the principle of lowest maintenance cost, thus concluding with the optimum maintenance abrasion value. Then the functional relation between abrasion loss and running time can be concluded with the gray model, thus the decision model in the optimum period with the lowest maintenance cost can be concluded.
منابع مشابه
High-Speed Railway Traction Power Supply Equipment Condition-Based Maintenance Decision Model Based on Reliability
Traction power supply equipments are the core part of the high-speed railway, so the maintenance of the power supply system is crucial for the security of the railway. Based on the research on the durable years of the traction power supply equipments, this paper puts forward the model of testing the traction power supply equipments of the reliable high speed railway. Some practical researches h...
متن کاملA Reliability Evaluation of High Speed Railway Traction Substation Based on the GO-FLOW Methodology
In order to assure the uninterrupted power supply of high speed railway, the reliability assessment of traction substation is essential at the design stage. Based on the system reliability engineering theory, a new system reliability analysis method called the GO-FLOW methodology is applied in the reliability assessment of traction substation of high speed railway. Considering failure and dynam...
متن کاملPower Quality Improvement in Traction Power Supply Networks
AC railway traction loads are usually huge single phase loads. As a result, a significant amount of Negative Sequence Current (NSC) is injected into utility grid. Moreover, harmonics and consumption ofreactive power are further power quality problems that the supply network is encountering. In this paper, acompensation strategy with the aid of Railway Power Conditioner (RPC) is proposed to over...
متن کاملA Direct Power Feeding System for AC Railway Networks Using Modular Multilevel Converter
Abstract Traditional railway power supply systems impose substantial power quality problems (PQ) on the utility network, such as unbalance, harmonics and a large amount of reactive power. This paper proposes a topology based on three-phase to single-phase modular multilevel converters (MMC) to obviate these problems. The MMC based traction substations (TSS) are connected directly to the utili...
متن کاملSimulatioin and Modelling of a Power Quality Compensator for Negative Sequence and Harmonic Currents in High Speed Electric Railway
This paper presents the designing of a power quality compensator to solve the power quality problem of negative-sequence and harmonic currents in high-speed railway traction systems. The proposed power quality compensator is constituted by railway static power conditioner (RPC), two thyristor-controlled reactors and two thyristor-controlled 3filters. The RPC contains two converters which are co...