BACKGROUND Mandibular movement analysis is a critical step in making the functional occlusal morphology and improving the diagnosis and treatment of temporomandibular joint disorders (TMDs). Cadiax Compact® is an electronic condylograph that claims to record the horizontal condylar inclination (HCI), Bennett angle (BA) and relative shape of the articular eminence. This study aims at assessing the accuracy of Cadiax Compact® II in its claimed abilities. MATERIALS AND METHODS The electronic condylograph (Cadiax Compact®II) was fitted on the fully adjustable articulator (gamma dental reference-SL). After setting of HCI and BA on the arbitrary degrees, eccentric movements were produced manually on the articulator. The Cadiax recorded these preadjusted angles and the accuracy of its recordings was assessed by comparison of the results with the preadjusted HCI, BA and color inserts as references. RESULTS The majority of the comparisons showed statistically significant differences between articulator settings and Cadiax recordings. However, the maximum difference was about 2.50 which seems acceptable for clinical practice. CONCLUSION The obtained results showed that Cadiax Compact is an accurate and reliable instrument for diagnostic purposes, yielding reproducible measurements. Despite this, Cadiax is a technically sensitive device that can preclude its routine usage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Condylar guidance settings on articulators from protrusive records.

lh e purpose of the protrusive jaw relation record is to adjust the condylar elements of the articulator so that they will present inclinations which are, as nearly as possible, similar or equivalent to those in the temporomandibular articulation. Most adjustable articulators for complete denture procedures will receive a protrusive interocclusal relation record, and the horizontal condylar inc...

متن کامل

Reproducibility of lateral excursive tooth contact in a semi-adjustable articulator depending on the type of lateral guidance.

The purposes of this study were (i) to compare the reproducibility of lateral tooth contacts of casts mounted in a semi-adjustable articulator when condylar guidance was set by different methods and (ii) to assess the margin of error of the variations of condylar guidance without changing lateral tooth contacts, depending on the type of lateral guidance. In subjects with different types of late...

متن کامل

Articulator-related registration--a simple concept for minimizing eccentric occlusal errors in the articulator.

PURPOSE The purpose of this study was to develop an easy-to-use procedure for individual registration and to test its accuracy. Unlike common principles, the method should be based on a transfer of the articulator geometry to the patient. MATERIALS AND METHODS The system consists of an articulator holding a bite plate in a standard position. The bite plate connects to an electronic recording ...

متن کامل

Comparative analysis of sagittal condylar guidance by protrusive interocclusal records with panoramic and lateral cephalogram radiographs in dentulous population: A clinico-radiographic study

AIM To evaluate and compare the correlation between sagittal condylar guidance obtained by protrusive interocclusal records mounted on semi-adjustable articulator with panoramic and Lateral cephalogram radiograph tracings in dentulous population. MATERIALS AND METHODS One-hundred twenty dentulous subjects between age group of 20-40 years, free of signs and symptoms of any temporomandibular di...

متن کامل

Evaluation of accuracy of transfer of the maxillary occlusal cant of two articulators using two facebow/semi-adjustable articulator systems: An in vivo study

AIM The aim of this study was to compare the accuracy of the angle made by Frankfort horizontal plane-occlusal plane on maxillary casts, mounted using the respective facebows on Artex Amann Girrbach and Hanau Wide-vue semi-adjustable articulators with cephalometrically derived Frankfort horizontal plane-occlusal plane angle as a control. SUBJECTS AND METHODS Maxillary casts of 30 subjects wer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 13 4  شماره 

صفحات  -

تاریخ انتشار 2012