Ultrahigh-resolution measurement by optical coherence tomography of dynamic tear film changes on contact lenses.

نویسندگان

  • Qi Chen
  • Jianhua Wang
  • Aizhu Tao
  • Meixiao Shen
  • Shuliang Jiao
  • Fan Lu
چکیده

Purpose. To determine the dynamic pre- and postlens tear film (PLTF and PoLTF) thicknesses by using optical coherence tomography (OCT). Methods. Ultrahigh-resolution OCT was used to image the tear film of 22 subjects before and after contact lens wear. A soft lens with 1 drop of artificial tears on its concave surface was inserted onto one randomly selected eye. OCT images were taken before insertion, immediately afterward, and every 2 minutes for 10 minutes. For the contralateral eye, the lens inserted was not prewetted on the concave surface. OCT images were taken before insertion, immediately afterward, and at 3 minutes. Then another drop was instilled, and images were taken immediately afterward and every 2 minutes for 10 minutes. Images were processed by custom software to yield tear film thickness. Results. The thickness of precorneal tear film (PCTF) was 1.9 +/- 0.9 mum. The PoLTF was visualized clearly in all cases immediately after lens insertion, with 1 drop on the lens concave surface. Through the first 6 minutes after insertion, the PoLTF was greater than the PCTF. The PLTF (n = 12) and PoLTF (n = 9) were visualized immediately after lens insertion. After 3 minutes, the PLTF in most subjects and PoLTF in all subjects were invisible. The thickness of the PLTF increased after the instillation of artificial tears, whereas the PoLTF did not at any checkpoint for 10 minutes. Conclusions. Ultrahigh-resolution OCT is a promising tool for measuring the tear film. The PoLTF did not increase after instillation of artificial tears.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic dynamic tear meniscus measurement in optical coherence tomography

An image processing algorithm is developed for quantitative assessment of tear meniscus dynamics from continuous optical coherence tomography (OCT) measurements. Clinical utility of dynamic OCT tear meniscus measurement is assessed in studies of tear meniscus parameters. The results indicate that any apparent changes in the early post-blink phase meniscus parameters are essentially related to t...

متن کامل

Precorneal and pre- and postlens tear film thickness measured indirectly with optical coherence tomography.

PURPOSE To demonstrate the feasibility of indirectly measuring the precorneal tear film thickness and pre- and postlens tear film (PLTF) thickness using optical coherence tomography (OCT). METHODS Central corneal thickness (C(1)) which includes the tear film (T) of both eyes of 40 non-contact lens wearers was measured using OCT after calibration. The mean age of the 40 subjects was 31.2 +/- 9...

متن کامل

Dynamic changes in ocular Zernike aberrations and tear menisci measured with a wavefront sensor and an anterior segment OCT.

PURPOSE To measure dynamic change characteristics of spatial and temporal variations in the post-blink tear film of normal eyes. METHODS A wavefront sensor was used to measure dynamic changes in wavefront aberrations, up to the seventh order, for 10 seconds in a group of 33 normal young adults. Tear menisci were imaged with an anterior segment optical coherence tomography (AS-OCT) system and ...

متن کامل

Upper and lower tear menisci on contact lenses.

PURPOSE The purpose of this study was to measure upper and lower tear menisci on contact lenses using real time optical coherence tomography (OCT). METHODS Both eyes of 20 adapted contact lens wearers were imaged when they wore two types of silicone hydrogel lenses, balafilcon A on one eye and galyfilcon A on the other eye. The height, radius, and area of upper and lower tear menisci were obt...

متن کامل

Optical coherence tomography to evaluate the interaction of different edge designs of four different silicone hydrogel lenses with the ocular surface

PURPOSE To evaluate the lens edge interaction with the ocular surface with different edge designs using optical coherence tomography and to examine the effect of lens power on the lens edge interactions. METHODS Four types of silicone hydrogel lenses with different edge designs (round-, semi-round-, chisel-, and knife-edged) at six different powers (+5.0, +3.0, +1.0, -1.0, -3.0, and -5.0 diop...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 51 4  شماره 

صفحات  -

تاریخ انتشار 2010