Inter-scan variability of coronary artery calcium scoring assessed on 64-multidetector computed tomography vs. dual-source computed tomography: a head-to-head comparison.

نویسندگان

  • Jelena R Ghadri
  • Robert Goetti
  • Michael Fiechter
  • Aju P Pazhenkottil
  • Silke M Küest
  • Rene N Nkoulou
  • Christina Windler
  • Ronny R Buechel
  • Bernhard A Herzog
  • Oliver Gaemperli
  • Christian Templin
  • Philipp A Kaufmann
چکیده

AIMS Coronary artery calcium (CAC) scoring has emerged as a tool for risk stratification and potentially for monitoring response to risk factor modification. Therefore, repeat measurements should provide robust results and low inter-scanner variability for allowing meaningful comparison. The purpose of this study was to investigate inter-scanner variability of CAC for Agatston, volume, and mass scores by head-to-head comparison using two different cardiac computed tomography scanners: 64-detector multislice CT (MSCT) and 64-slice dual-source CT (DSCT). METHODS AND RESULTS Thirty patients underwent CAC measurements on both 64-MSCT (GE LightSpeed XT scanner: 120 kV, 70 mAs, 2.5 mm slices) and 64-DSCT (Siemens Somatom Definition: 120 kV, 80 mAs, 3 mm slices) within <100 days (0-97). Retrospective intra-scan comparison revealed an excellent correlation. The excellent intra-scan (inter-observer) agreement was documented by narrow limits of agreement and a correlation coefficient of variation (COV) of r ≥ 0.99 (P < 0.001) for all CAC scores with a low COV for both scanners (64-MSCT/64-DSCT), i.e. Agatston (2.0/2.1%), mass (3.0/2.0%), and volume (4.7/3.9%). Inter-scanner comparison revealed larger Bland-Altman (BA) limits of agreement, despite high correlation (r ≥ 0.97) for all scores, with COV at 15.1, 21.6, and 44.9% for Agatston, mass, and volume scores. The largest BA limits were observed for volume scores (-1552.8 to 574.2), which was massively improved (-241.0 to 300.4, COV 11.5%) after reanalysing the 64-DSCT scans (Siemens) with GE software/workstation (while Siemens software/workstation does not allow cross-vendor analysis). Phantom measurements confirmed overestimation of volume scores by 'syngo Ca-Scoring' (Siemens) software which should therefore be reviewed (vendor has been notified). CONCLUSION Intra- and inter-scan agreement of CAC measurement in a given data set is excellent. Inter-scanner variability is reasonable, particularly for Agatston units in the clinically most relevant range <1000. The use of different software solutions has a greater influence particularly on volume scores than the use of different scanner types.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Giant aneurysm of the right sinus of Valsalva causing right ventricular outflow obstruction.

Validation of a new contrast material protocol adapted to body surface area for optimized low-dose CT coronary angiography with prospective ECG-triggering. Int J Cardiovasc Imaging 2010;26:591–7. 13. Tatsugami F, Husmann L, Herzog BA, Burkhard N, Valenta I, Gaemperli O et al. Evaluation of a body mass index-adapted protocol for low-dose 64-MDCT coronary angiography with prospective ECG triggeri...

متن کامل

Clinical applications of virtual, non-contrast head images derived from dual-source, dual-energy cerebrovascular computed tomography angiography

Background: This study set out to evaluate the utility of cerebrovascular virtual non-contrast (VNC) scans. Materials and Methods: Conventional non-contrast (CNC) and dual-energy computed tomography angiography (DE-CTA) head scans were conducted on 100 subjects, of which 46 were normal, 15 had parenchymal hematomas of the brain, 13 had ischemic infarction, 22 had tumors, and 4 had calcified les...

متن کامل

Cardiac multidetector computed tomography: where do we stand?

Multidetector-row CT (MDCT) scanners for the noninvasive detection of coronary artery disease (CAD) were introduced in 1999, with the 4-slice scanners that allowed small and rapidly moving structures like the coronary arteries to be visualized with sufficient image quality. Soon, the technology advanced further, with the introduction of 16-, 40-, and 64-slice scanners (current systems) and prot...

متن کامل

Relationship between Coronary Artery Calcium Score by Multidetector Computed Tomography and Plaque Components by Virtual Histology Intravascular Ultrasound

The aim of this study was to evaluate the relationship between coronary artery calcium score (CACS) assessed by multidetector computed tomography (MDCT) and plaque components assessed by virtual histology-intravascular ultrasound (VH-IVUS) in 172 coronary artery disease (CAD) patients with 250 coronary lesions. CACS was assessed according to Agatston scoring method by MDCT and patients were div...

متن کامل

Association of aortic root calcification severity with the extent of coronary artery calcification assessed by calcium-scoring dual-source computed tomography.

PURPOSE To investigate the association between aortic root calcification (ARC) and coronary artery calcification (CAC) assessed by coronary artery calcium-scoring dual-source computed tomography (DSCT). MATERIALS AND METHODS We retrospectively analyzed 143 consecutive patients who underwent coronary artery calcium-scoring during coronary DSCT angiography. 57 patients had findings of ARC on ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 32 15  شماره 

صفحات  -

تاریخ انتشار 2011