A planar interdigitated ring electrode array via dielectrophoresis for uniform patterning of cells.

نویسندگان

  • Lo-Chang Hsiung
  • Chun-Hui Yang
  • Chi-Li Chiu
  • Chen-Lin Chen
  • Yueh Wang
  • Hsinyu Lee
  • Ji-Yen Cheng
  • Ming-Chih Ho
  • Andrew M Wo
چکیده

Uniform patterning of cells is highly desirable for most cellular studies involving cell-cell interactions but is often difficult in an in vitro environment. This paper presents the development of a collagen-coated planar interdigitated ring electrode (PIRE) array utilizing positive dielectrophoresis to pattern cells uniformly. Key features of the PIRE design include: (1) maximizing length along the edges where the localized maximum in the electric field exists; (2) making the inner gap slightly smaller than the outer gap in causing the electric field strength near the center of a PIRE being generally stronger than that near the outer edge of the same PIRE. Results of human hepatocellular carcinoma cells, HepG2, adhered on a 6x6 PIRE array show that cells patterned within minutes with good uniformity (48+/-6 cells per PIRE). Cell viability test revealed healthy patterned cells after 24h that were still confined to the collagen-coated PIREs. Furthermore, quantification of fluorescence intensity of living cells shows an acceptable reproducibility of cell viability among PIREs (mean normalized intensity per PIRE was 1+/-0.138). The results suggest that the PIRE array would benefit applications that desire uniform cellular patterning, and improve both response and reproducibility of cell-based biosensors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Geometric and material determinants of patterning efficiency by dielectrophoresis.

Dielectrophoretic (DEP) forces have been used extensively to manipulate, separate, and localize biological cells and bioparticles via high-gradient electric fields. However, minimization of DEP exposure time is desirable, because of possible untoward effects on cell behavior. Toward this goal, this article investigates the geometric and material determinants of particle patterning kinetics and ...

متن کامل

Controlling two-dimensional movement of microparticles over an electrode array surface.

This paper presents an original microchip device that manipulates planar x- and y-positions of dielectric microbeads over an electrode array with dielectrophoresis (DEP) effects. Implemented with a simple single-layer metal process, the microchip device consists of two parallel arrays of triangular-shaped electrodes. The two arrays of electrodes are arranged such that they locked into each othe...

متن کامل

A Concept of Moving Dielectrophoresis Electrodes Based on Microelectromechanical Systems (mems) Actuators

A concept of moving dielectrophoresis electrodes (MDEP) based on Microelectromechanical Systems (MEMS) actuators is introduced in this letter. An example design of tuneable dielectrophoresis filter is presented. Finite Element Analysis of the electrostatic field of the tuneable filter has been conducted. Results show that the trapping force can be adjusted by actuating the MEMS actuators. The p...

متن کامل

Rapid heterogeneous liver-cell on-chip patterning via the enhanced field-induced dielectrophoresis trap.

Biomimetic heterogeneous patterning of hepatic and endothelial cells, which start from randomly distributed cells inside the microfluidic chamber, via the chip design of enhanced field-induced dielectrophoresis (DEP) trap is demonstrated and reported in this paper. The concentric-stellate-tip electrode array design in this chip generates radial-pattern electric fields for the DEP manipulation o...

متن کامل

Bacterial handling under the influence of non-uniform electric fields: dielectrophoretic and electrohydrodynamic effects.

This paper describes the modeling and experimental verification of a castellated microelectrode array intended to handle biocells, based on common dielectrophoresis. The proposed microsystem was developed employing platinum electrodes deposited by lift-off, silicon micromachining, and photoresin patterning techniques. Having fabricated the microdevice it was tested employing Escherichia coli as...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biosensors & bioelectronics

دوره 24 4  شماره 

صفحات  -

تاریخ انتشار 2008