A hemoglobin based oxygen carrier, bovine polymerized hemoglobin (HBOC-201) versus Hetastarch (HEX) in an uncontrolled liver injury hemorrhagic shock swine model with delayed evacuation.

نویسندگان

  • Jennifer Gurney
  • Nora Philbin
  • Jennifer Rice
  • Françoise Arnaud
  • Feng Dong
  • Meghan Wulster-Radcliffe
  • L Bruce Pearce
  • Lewis Kaplan
  • Richard McCarron
  • Daniel Freilich
چکیده

BACKGROUND As HBOC-201 improves outcome in animals with hemorrhagic shock (HS), we compared HBOC-201 and HEX (used by U.S. military special operations forces) in a swine model of delayed evacuation and uncontrolled HS. METHODS Twenty-four Yucatan pigs underwent a grade III liver injury and were resuscitated with HBOC-201, HEX, or no fluid (NON). Additional infusions were given for hypotension or tachycardia. After 4 hours, the liver was repaired; IV fluids and blood transfusions were administered. Pigs were monitored for 72 hours. RESULTS Survival was 7/8, 1/8, and 1/8 in HBOC-201-, HEX-, and NON-resuscitated pigs, respectively. Compared with HEX, HBOC-201 pigs had higher systemic and pulmonary artery pressures and had comparable cardiac outputs, but were less tachycardic. Transcutaneous tissue oxygenation was restored more rapidly in HBOC-201 pigs, there was a trend to lower lactic acid, and base deficit was less. HBOC-201 pigs had lower fluid requirements, higher urine output, and lower blood loss than HEX pigs. CONCLUSIONS Despite evidence of vasoactivity, HBOC-201 more effectively stabilized tissue oxygenation, reversed anaerobic metabolism, decreased bleeding, and increased survival in comparison with HEX. If confirmed in clinical trials, these data suggest that for the resuscitation of combat casualties with delayed evacuation and uncontrolled HS due to solid organ injury, HBOC-201 is a superior low-volume resuscitative fluid.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A hemoglobin-based oxygen carrier, bovine polymerized hemoglobin (HBOC-201) versus hetastarch (HEX) in a moderate severity hemorrhagic shock swine model with delayed evacuation.

OBJECTIVE To evaluate the efficacy of HBOC-201 for resuscitation of hemorrhagic shock in a swine model incorporating soft tissue injury and delayed evacuation. METHODS A muscle crush injury and 40% estimated blood volume controlled hemorrhage was completed in 24 Yucatan mini-pigs. Pigs were untreated or resuscitated with HBOC-201 or 6% hetastarch (HEX) at 20 min. Invasive hemodynamics and cli...

متن کامل

Effects of bovine polymerized hemoglobin on coagulation in controlled hemorrhagic shock in swine.

HBOC-201, a bovine polymerized hemoglobin, has been proposed as a novel oxygen-carrying resuscitative fluid for patients with hemorrhagic shock (HS). Herein, we evaluated the hemostatic effects of HBOC-201 in an animal model of HS. A 40% blood loss-controlled hemorrhage and soft tissue injury were performed in 24 invasively monitored Yucatan mini-pigs. Pigs were resuscitated with HBOC-201 (HBOC...

متن کامل

Innate immune response after resuscitation with hemoglobin-based oxygen carrier and recombinant factor VIIA in uncontrolled hemorrhagic shock in a swine model.

BACKGROUND Rapid resuscitation with oxygen-carrying fluids is critically important in hemorrhagic shock (HS) combat casualties in remote areas where blood is not available. Hemoglobin-based oxygen carrier-201 (HBOC-201) has been shown to increase survival and reduce immune activation following HS in animal models. Recombinant factor VIIa (rfVIIa), a systemic hemostatic agent, is Food and Drug A...

متن کامل

The effect HBOC-201 and sodium nitrite resuscitation after uncontrolled haemorrhagic shock in swine.

BACKGROUND Development of Haemoglobin-based oxygen carriers (HBOCs) as blood substitutes has reached an impasse due to clinically adverse outcomes attributed to vasoconstriction secondary to nitric oxide (NO) scavenging. Studies suggest haemoglobin exhibits nitrite reductase activity that generates NO and N(2)O(3); harnessing this property may offset NO scavenging. Therefore, the effects of con...

متن کامل

Hemoglobin-based Oxygen Carrier (HBOC-201) and Escalating Doses of Recombinant Factor VIla (rFVIIa) as a Novel Pre-hospital Resuscitation Fluid in a Swine Model of Severe Uncontrolled Hemorrhage

Exsanguinating hemorrhage and unavailability of blood are major problems in pre-hospital trauma care. We investigated if combining rFVIIa with HBOC-201 reduces blood loss and improves physiologic parameters compared to HBOC alone. Swine underwent liver injury and were resuscitated with HBOC-201 alone or HBOC+90, 180 or 360 J.lg/kg rFVIIa before hospital arrival at 240 min; animals survived to 7...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of trauma

دوره 57 4  شماره 

صفحات  -

تاریخ انتشار 2004