A hospital cost analysis of a fibrin sealant patch in soft tissue and hepatic surgical bleeding
نویسندگان
چکیده
BACKGROUND Despite hemostat use, uncontrolled surgical bleeding is prevalent. Drawbacks of current hemostats include limitations with efficacy on first attempt and suboptimal ease-of-use. Evarrest® is a novel fibrin sealant patch that has demonstrated high hemostatic efficacy compared with standard of care across bleeding severities. The objective of this study was to conduct a hospital cost analysis of the fibrin sealant patch versus standard of care in soft tissue and hepatic surgical bleeding. METHODS The analysis quantified the 30-day costs of each comparator from a hospital perspective. Published US unit costs were applied to resource use (ie, initial treatment, retreatment, operating time, hospitalization, transfusion, and ventilator) reported in four trials. A "surgical" analysis included resources clinically related to the hemostatic benefit of the fibrin sealant patch, whereas a "hospital" analysis included all resources reported in the trials. An exploratory subgroup analysis focused solely on coagulopathic patients defined by abnormal blood test results. RESULTS The surgical analysis predicted cost savings of $54 per patient with the fibrin sealant patch compared with standard of care (net cost impact: -$54 per patient; sensitivity range: -$1,320 to $1,213). The hospital analysis predicted further cost savings with the fibrin sealant patch (net cost impact of -$2,846 per patient; sensitivity range: -$1,483 to -$5,575). Subgroup analyses suggest that the fibrin sealant patch may provide dramatic cost savings in the coagulopathic subgroup of $3,233 (surgical) and $9,287 (hospital) per patient. Results were most sensitive to operating time and product units. CONCLUSION In soft tissue and hepatic problematic surgical bleeding, the fibrin sealant patch may result in important hospital cost savings.
منابع مشابه
PREPARATION OF FIBRIN GLUE AS A BIOLOGICAL SEALANT TO CONTROL BLEEDING IN HEART MUSCLE AND BLOOD VESSELS
Fibrin glue is used for control of bleeding in various surgical procedures. In this work the ability of fibrin glue to seal punctures in the vascular system is demonstrated. Blood samples were taken from rabbits, fibrinogen was separated and fibrin glue was eventually prepared. The rabbits were anesthetized and a midline incision was carried out. The heart and abdominal aorta were exposed. ...
متن کاملCollagen fleece-bound fibrin sealant is not associated with an increased risk of thromboembolic events or major bleeding after its use for haemostasis in surgery: a prospective multicentre surveillance study
BACKGROUND Topical haemostatic agents are used to help achieve haemostasis during surgery when standard surgical techniques are insufficient. The objective of this study was to confirm the safety profile of an equine collagen patch coated with human fibrinogen and human thrombin with particular focus on the occurrence of thromboembolic events (TEEs), major bleeding and immunological events. M...
متن کاملThe Evaluation of Fibrin Sealants and Tissue Adhesives in Oral Surgery Among Patients with Bleeding Disorders
OBJECTIVE The aim of this study was to evaluate the efficiency of two local hemostatic agents administered with apreoperative dose of replacement therapy in patients with bleeding disorders undergoing oral surgery. MATERIAL AND METHODS The study included 21 patients that were randomly divided into 3 groups. Patients in Group1 (n = 7) received preoperative replacement therapy and postoperative...
متن کاملمقایسه اثر کلسیم سولفات و کلرید فریک در کنترل خونریزی طی جراحی کبدی؛ مطالعه مدل حیوانی
Background and Objective: The control of parenchymal hemorrhage especially in liver parenchyma, despite improvements in surgical science, is still one of the challenges that surgeons are facing with. Therefore, introducing an effective method to control liver bleeding is of important research priority. This study aimed to compare the hemostatic effect of calcium sulfate and ferric chloride on c...
متن کاملRandomized clinical trial of tranexamic acid-free fibrin sealant during vascular surgical procedures.
BACKGROUND This study evaluated the safety and haemostatic effectiveness of a fibrin sealant (EVICEL(™) Fibrin Sealant (Human)) during vascular surgery. METHODS This prospective randomized controlled trial compared the haemostatic effectiveness of fibrin sealant (75 patients) or manual compression (72) in polytetrafluoroethylene (PTFE) arterial anastomoses. The primary endpoint was the absenc...
متن کامل