Evaluation of a rhodamine-WT dye/glycerin mixture as a tracer for testing direct injection systems for agricultural sprayers
نویسندگان
چکیده
The purpose of this study was to provide valuable insight regarding the use of Rhodamine WT (red) dye as a tracer for evaluating injected concentrations. More specifically, the effects of mixing the dye with glycerin to simulate the viscosity of a pesticide (e.g., glyphosate) or injecting the dye/glycerin mixture into deionized (DI) versus tap water on developing appropriate calibration equations were evaluated. Test results indicated that mixing the dye in a solution of glycerin and DI water significantly affected absorbance measurements compared to the dye mixed solely in DI water. The error in estimating absorbance was 7.4% between the two calibration equations. Therefore, any calibration curves must include a solution containing glycerin to compensate for this. Absorbance results also indicated that potable tap water could be used to simulate the spray carrier as opposed to the DI water. A calibration curve was developed for the simulated pesticide (dye/glycerin/DI water solution) injected into the carrier (tap water) for solutions ranging from 2,000:1 (carrier:pesticide) to 500,000:1; an overall dilution range of 250:1. This dilution range exceeded typical pesticide tank-mixed dilutions which were on the order of 11:1 for the application of glyphosate for corn or soybeans. The regression model standard error for predicting the dye concentration based on absorbance measurements was 5.3x10.
منابع مشابه
Application of Tracer Techniques to Continuous-flow Toxicity Testing
-Frequent toxicant analyses are essential for good quality data in long-term continuous-flow tests. Due to the time consuming and costly chemical analyses, exposure levels are measured at best on a daily basis. These infrequent determinations may not detect variability in toxicant concentrations that could result in test failures. To minimize repetitive testing and improve data quality, a dye t...
متن کاملA preliminary examination of an in situ dual dye approach to measuring light fluxes in lotic systems
Light is a critical parameter in aquatic ecosystems, affecting primary production and in situ photochemistry. However, measuring light exposure for suspended particles or dissolved components in a dynamic water column can be challenging with existing Eulerian approaches. Here, we assess the simultaneous deployment of two dyes differing in photolability (rhodamine WT and fluorescein) as a Lagran...
متن کاملEvaluation of radiolabeled streptokinase for thrombosis imaging
Introduction: Cardiovascular disease is the major cause of morbidity and mortality in developing and developed countries. Rapid diagnosis of the thrombosis can be an essential step in management of the stroke. Methods: In this work a recently developed radiolabeled streptokinase (STP) tracer was evaluated in an animal thrombotic model using SPECT imaging and biodis...
متن کاملCanopy penetration and deposition of barrier sprays from electrostatic and conventional sprayers.
An experimental study was conducted to investigate the usefulness of electrostatic and conventional sprayers for barrier applications. Two conventional and three electrostatic sprayers were used in the study. Usefulness of the sprayers was rated based on penetration of spray into and deposition onto 2 sides of leaves on natural vegetation. Bifenthrin (Talstar adulticide) was applied at labeled ...
متن کاملAir-fuel Mixture Preparation for Internal Combustion Engines:Optical Techniques for Diagnosis of the Spray Developments
Nobody escapes the importance of the air/fuel mixture preparation in internal combustion engines, whatever is the thermodynamic cycle they work on and the adopted fuel. The short time between the fueling and the start of the combustion is crucial for the best mixture formation and its burning for energy optimization and the pollutant production. The always stringent vehicle emissions rules led ...
متن کامل