Continuous monitoring of intrathoracic impedance and right ventricular pressures in patients with heart failure.

نویسندگان

  • Marc Vanderheyden
  • Richard Houben
  • Sofie Verstreken
  • Marcus Ståhlberg
  • Pascalle Reiters
  • Roger Kessels
  • Frieder Braunschweig
چکیده

BACKGROUND Hemodynamic monitoring using implantable devices may provide early warning of volume overload in patients with heart failure (HF). This study was designed to prospectively compare information from intrathoracic impedance monitoring and continuous right ventricular pressure measurements in patients with HF. METHODS AND RESULTS Sixteen patients with HF (age, 63.5+/-13.8 years; left ventricular ejection fraction, 23.2+/-11.3%; New York Heart Association, II and III) and a previous HF decompensation received both a cardiac resynchronization therapy defibrillator providing a daily average of intrathoracic impedance and an implantable hemodynamic monitor providing an estimate of the pulmonary artery diastolic pressure. At the end of a 6-month investigator-blinded period, baseline reference hemodynamic values were determined over 4 weeks during which the patient was clinically stable. A major HF event was defined as HF decompensation requiring hospitalization, IV diuretic treatment, or leading to death. Sixteen major HF events occurred in 10 patients. Within 30 days and 14 days before a major HF event, impedance decreased by 0.12+/-0.21 Omega/d and 0.20+/-0.20 Omega/d, respectively, whereas estimated pulmonary arterial diastolic pressure increased by 0.10+/-0.20 mm Hg/d and 0.16+/-0.15 mm Hg/d, respectively. During these periods, impedance decreased by 3.8+/-5.4 Omega (P<0.02) and 4.9+/-6.1 Omega (P<0.007), respectively, whereas estimated pulmonary arterial diastolic pressure increased by 5.8+/-5.7 mm Hg (P<0.002) and 6.8+/-6.1 mm Hg (P<0.001), respectively, compared with baseline. In all patients, impedance and estimated pulmonary arterial diastolic pressure were inversely correlated (r = -0.48+/-0.25). Within 30 days preceding a major HF event, this correlation improved to r =-0.58+/-0.24. CONCLUSIONS Decompensated HF develops based on hemodynamic derangements and is preceded by significant changes in intrathoracic impedance and right ventricular pressures during the month prior to a major clinical event. Impedance and pressure changes are moderately correlated. Future research may establish the complementary contribution of both parameters to guide diagnosis and management of patients with HF by implantable devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intrinsic PEEP and cardiopulmonary interaction in patients with COPD and acute ventilatory failure.

Deviation of end-expiratory lung volume from the elastic equilibrium volume of the respiratory system is recognized as a cardinal feature in mechanically-ventilated patients with severe chronic obstructive pulmonary disease (COPD) and acute ventilatory failure (AVF). The presence of dynamic hyperinflation implies that alveolar pressure remains positive throughout expiration. At the end of the e...

متن کامل

Significant increase in the incidence of ventricular arrhythmic events after an intrathoracic impedance change measured with a cardiac resynchronization therapy defibrillator.

BACKGROUND Cardiac resynchronization therapy defibrillator (CRT-D) devices are now capable of monitoring changes in intrathoracic impedance. Intrathoracic impedance monitoring resulting in a fluid index threshold crossing has been proven to predict heart failure (HF) exacerbations. We retrospectively investigated the relationship between changes in intrathoracic impedance and the occurrence of ...

متن کامل

Ambulatory monitoring of congestive heart failure by multiple bioelectric impedance vectors.

OBJECTIVES This study was designed to investigate the properties of multiple bioelectric impedance signals recorded during congestive heart failure (CHF) by utilizing various electrode configurations of an implanted cardiac resynchronization therapy system. BACKGROUND The monitoring of CHF has relied mainly on right-side heart sensors. METHODS Fifteen normal dogs underwent implantation of c...

متن کامل

Acute heart failure as "acute endothelitis"--Interaction of fluid overload and endothelial dysfunction.

Acute heart failure (AHF) is defined as a change in heart failure (HF) symptoms (i.e. dyspnoea, abdominal bloating, and fatigue) and signs (i.e. pulmonary crackles, jugular vein distension, and peripheral oedema) resulting in a need for urgent therapy. Symptoms and signs of HF are due to elevated left and right ventricular filling pressures with or without low cardiac output [1]. Heart failure ...

متن کامل

Intrathoracic impedance monitoring in patients with heart failure: correlation with fluid status and feasibility of early warning preceding hospitalization.

BACKGROUND Patients with heart failure are frequently hospitalized for fluid overload. A reliable method for chronic monitoring of fluid status is therefore desirable. We evaluated an implantable system capable of measuring intrathoracic impedance to identify potential fluid overload before heart failure hospitalization and to determine the correlation between intrathoracic impedance and standa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Heart failure

دوره 3 3  شماره 

صفحات  -

تاریخ انتشار 2010