Bench testing of a knee joint arthrometer.

نویسندگان

  • Massimo G Barcellona
  • Tony Christopher
  • Matthew C Morrissey
چکیده

The KT1000 and KT2000 knee joint arthrometers (MEDmetric Corp, San Diego, California) have been shown to overestimate the measurement of knee joint sagittal laxity. The purpose of this study was to investigate the accuracy of the KT arthrometers as measures of anterior and posterior linear displacement. The anterior and posterior linear displacements of 3 KT arthrometers (2 KT1000 arthrometers and 1 KT2000 arthrometer) were compared with the simultaneous displacement measured by a precision linear Vernier Dial Test Indicator (Davenport Ltd, London, United Kingdom). The displacement calculated using the analog output of the KT2000 was also compared with the values on the KT2000 displacement dial. Compared with the Vernier Dial Test Indicator, the KT arthrometers overestimated anterior linear displacement by between 22% and 24%. True anterior displacement for all 3 arthrometers, as recorded by the Vernier Dial Test Indicator, was found by multiplying the KT value by 0.79. When compared with the Vernier Dial Test Indicator, the KT arthrometers underestimated posterior linear displacement by between 18% and 19%. True posterior displacement, as recorded by the Vernier Dial Test Indicator, was found by multiplying the KT1000 value by 1.17 and the KT2000 value by 1.16. The internal apparatus of the KT2000 and KT1000 knee joint arthrometers overestimates anterior displacement and underestimates posterior displacement with a predictable relative systematic error. Future validation studies should use these correction equations to assess the accuracy of the KT arthrometers. Sagittal plane knee laxity measured with the KT devices requires systematic correction for optimal accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterisation of in-vivo mechanical action of knee braces regarding their anti-drawer effect.

BACKGROUND The knee joint is vulnerable to various injuries and degenerative conditions, potentially leading to functional instability. Usual treatments involve knee orthoses to support the joint. However, the level of mechanical action of these devices remains controversial despite high prescription and demand. METHODS The mechanical ability of three commercial hinged knee braces and one sle...

متن کامل

Quantitative analysis of the measuring capabilities of the KT-1000 knee ligament arthrometer.

The KT-1000 arthrometer was evaluated in vitro and in vivo to determine accuracy and quantify effects of potential error sources in clinical application. The KT-1000 arthrometer in vitro accuracy was evaluated by making 30 measurements of 13 known displacements (range, +15 to -15 mm). The effect of applied force on malalignment measurements was evaluated in vitro by making repeated measurements...

متن کامل

Robotic knee laxity testing: reliability and normative data.

PURPOSE To evaluate the reliability of the GeNouRoB knee arthrometer and present normative values of knee anterior laxity using this device on young females. METHODS Anterior laxity in both knees was tested in two groups of young, uninjured females using the hamstrings electromyography biofeedback feature of the device. There were 13 participants in the group tested for reliability and 23 for...

متن کامل

ارزیابی نتایج بالینی روش مدیالیزه کردن ورودی تونل تیبیا در بازسازی لیگامان صلیبی قدامی

Introduction: Purpose of this study was to evaluate outcome of Anterior Cruciate Ligament (ACL) reconstruction surgery with a medial tibia tunnel entrance in patients with rupture of the ligament. Methods: This cross-sectional study was performed in patients admitted to Sina Hospital in Tehran from April 2009 to April 2011. ACL reconstruction was done by arthroscopic surgery and the patients ...

متن کامل

Hot and cold whirlpool treatments and knee joint laxity.

OBJECTIVE To examine the influence of clinical applications of heat and cold on arthrometric laxity measurements of the knee. DESIGN AND SETTING The knee joint was submersed 4 inches above the patella in hot and cold whirlpools containing water of 40 degrees C and 15 degrees C for 20 minutes. A control was also performed to provide a neutral temperature comparison group. SUBJECTS Eight male...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 36 8  شماره 

صفحات  -

تاریخ انتشار 2013