Percutaneous closure of a paravalvular leak 4 years after mitral valve replacement.

نویسندگان

  • Alain Delabays
  • Eric Eeckhout
  • Pierre Vogt
چکیده

cellular compartmentation of troponin T: release kinetics after global ischemia and calcium paradox in the isolated perfused rat heart. J Mol Cell Cardiol 1995; 27:793–803. 23. Vikenes K, Westby J, Matre K, Kuiper KK, Farstad M, Nordrehaug JE. Release of cardiac troponin I after temporally graded acute coronary ischaemia with electrocardiographic ST depression. Int J Cardiol 2002;85:243–251. 24. Suleiman MS, Lucchetti V, Caputo M, Angelini GD. Short periods of regional ischaemia and reperfusion provoke release of troponin I from the human hearts. Clin Chim Acta Int J Clin Chem 1999;284:25–30. 25. Blumgart HL, Gilligan DR, Schlesinger MJ. Experimental studies of the effect of temporary occlusion of coronary arteries. Am Heart J 1941;22:374–389. 26. Wallace TW, Abdullah SM, Drazner MH, Das SR, Khera A, McGuire DK, Wians F, Sabatine MS, Morrow DA, de Lemos JA. Prevalence and determinants of troponin T elevation in the general population. Circulation 2006;113: 1958–1965. 27. Latini R, Masson S, Anand IS, Missov E, Carlson M, Vago T, Angelici L, Barlera S, Parrinello G, Maggioni AP, Tognoni G, Cohn JN. Prognostic value of very low plasma concentrations of troponin T in patients with stable chronic heart failure. Circulation 2007;116:1242–1249. 28. Apple FS, Wu AH, Jaffe AS. European Society of Cardiology and American College of Cardiology guidelines for redefinition of myocardial infarction: how to use existing assays clinically and for clinical trials. Am Heart J 2002;144: 981–986.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous closure of mitral paravalvular leak.

Paravalvular leak (PVL) is a complication observed in patients after prosthetic valve replacement. The incidence of PVL is estimated as 2-3%. The cause of PVL may be paravalvular infection, suture continuity disruption, damage of tissues around the annulus or limitation of disc mobility by thrombus or vegetation. The preferable method of treatment of PVL is surgery. Recently, percutaneous closu...

متن کامل

Percutaneous Treatment of Mitral Valve Periprosthetic Leakage. An Alternative to High-Risk Surgery?

Received February 6, 2008. Accepted for publication May 27, 2008. Periprosthetic mitral valve regurgitation due to paravalvular leakage is one of the complications of valve replacement surgery. We report a series of 8 patients with severe symptomatic periprosthetic mitral regurgitation in whom surgery could not be performed because of the high risk. All patients were assigned to percutaneous cl...

متن کامل

Percutaneous transcatheter closure of prosthetic mitral paravalvular leaks: are we there yet?

A potential complication of mitral valve replacement surgery is the development of a paravalvular leak (PVL). Percutaneous transcatheter closures of PVLs using a wide array of devices have been reported in the literature, although the procedural success rate of this approach remains variable. One major challenge of transcatheter mitral PVL closure lies in the ability to adequately visualize the...

متن کامل

Failed percutaneous closure of a mitral prosthesis paravalvular leak.

A 77-year-old man who had a mechanical prosthetic mitral valve and aortic valve implanted in 1993 presented dyspnea and anemia, and was diagnosed of mitral prosthesis paravalvular leak. The patient was considered at high operative risk owing to his age, severe pulmonary hypertension, chronic renal failure, and previous cardiac surgery. Surgical treatment in his reference hospital was therefore ...

متن کامل

Percutaneous treatment of mitral valve periprosthetic leakage. An alternative to high-risk surgery?

Periprosthetic mitral valve regurgitation due to paravalvular leakage is one of the complications of valve replacement surgery. We report a series of eight patients with severe symptomatic periprosthetic mitral regurgitation in whom surgery could not be performed because of the high risk. All patients were assigned to percutaneous closure of periprosthetic mitral valve leaks using an Amplatzer ...

متن کامل

Bioprosthetic leaflet erosion after percutaneous mitral paravalvular leak closure.

Davis nline ranscatheter closure of prosthetic paravalvular eaks is increasingly performed at experienced enters (1–3). The lack of devices dedicated to aravalvular leak closure has not deterred the ff-label use of various occluder devices. These mages illustrate the potential complexity of ranscatheter paravalvular leak repair with the eed for additional occluder placement, and the evelopment ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 30 2  شماره 

صفحات  -

تاریخ انتشار 2009