چکیده

The loading of needles for loose seed implantation of the prostate gland results requires a significant amount of effort and some radiation exposure to members of the medical staff. This study was performed to quantify the time spent and exposure levels associated with implant preparation, as well as to investigate any improvement in the time or exposure burden due to the introduction of a new loading device. The movements and radiation exposures for two single, highly experienced dosimetrists were monitored for ten conventionally loaded iodine implant cases. These same cases were reloaded with dummy sources using the sleeved system to determine time savings, if any. Two of these ten cases were then loaded with live sources using the sleeved system to determine relative exposure to the loading staff between the two methods. The results were then analyzed to generate per-seed and per-needle loading time and exposure burdens. Formulas are presented that may be used to determine the average time to load implants and the resultant staff exposure, both with the conventional technique and with the sleeved method. On the average, it takes an experienced loader 48 min to prepare an implant for the operating room, receiving a hand dose of about 10 mrem and a whole body dose of about 1 mrem. The sleeved system reduced these values by at least half. The time and exposure burden associated with the preparation of iodine loose seed implants has been characterized. The use of the sleeved needles resulted in significant time and exposure reductions for the medical staff.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Capacitive Hyperthermia as an Alternative to Brachytherapy in Treatment of Human Prostate Cancer Cell

Introduction: The aim of this study was the evaluation of induced DNA damages of human prostate cancer cells, DU-145, treated with a combination of radiofrequency capacitive hyperthermia (HT) and teletherapy (EBRT) compared to a combination of teletherapy with high dose rate brachytherapy (BR).   Materials and Methods: DU-145 cells were cultured as spheroids ...

متن کامل

A comparison of preplan MRI and preplan CT-based prostate volume with intraoperative ultrasound-based prostate volume in real-time permanent brachytherapy

PURPOSE The present study compared the difference between intraoperative transrectal ultrasound (iTRUS)-based prostate volume and preplan computed tomography (CT), preplan magnetic resonance imaging (MRI)-based prostate volume to estimate the number of seeds needed for appropriate dose coverage in permanent brachytherapy for prostate cancer. MATERIALS AND METHODS Between March 2007 and March ...

متن کامل

The phylogeny of permanent prostate brachytherapy

Permanent prostate brachytherapy has been practiced for more than a century. This review examines the influence of earlier procedures on the modern transperineal ultrasound-directed technique. A literature review was conducted to examine the origin of current clinical practice. The dimensions of the modern brachytherapy seed, the prescription dose, and implant/teletherapy sequencing are vestigi...

متن کامل

Historical review of interstitial prostate brachytherapy

In the recent years, interstitial brachytherapy implantation has become the treatment of choice for early stage prostate cancer patients. Treatment of prostate cancer with radiation is traced back to 1909. Originally this treatment modality was very crude and could not gain much popularity till 1982. Advancements in radioactive source designs, introduction of new low energy radioactive sources,...

متن کامل

The Effect of Scattering from Leg Region on Organ Doses in Prostate Brachytherapy for 103Pd, 125I and 131Cs Seeds

Introduction Dose calculation of tumor and surrounding tissues is essential during prostate brachytherapy. Three radioisotopes, namely, 125I, 103Pd, and 131Cs, are extensively used in this method. In this study, we aimed to calculate the received doses by the prostate and critical organs using the aforementioned radioactive seeds and to investigate the effect of scattering contribution for the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2002